—5—
ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)
1.
Coastal Filter
A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow.
Usage Guideline:
Suggested in geographic areas where salt damage could occur.
2.
Outdoor Air Temperature Sensor
A device that allows the temperature at a remote location (outdoors) to be displayed at the thermostat.
Usage Guideline:
Suggested in all Bryant programmable thermostats.
3.
Piston Kit
Some combinations of the 2-speed heat pumps designed with Puron refrigerant require changing the outdoor piston to achieve rated heating performance.
Usage Guideline:
Required in the following combinations:
698B036 matched with FV4/FK4, and FE4-005, 006.
698B048 matched with FV4/FK4, and FE4-006.
Refer to the KHAPX0201CPA Installation Instructions for details.
4.
Pressure Guard Kit
A pressure switch kit that cycles the outdoor fan to limit the heating head pressure below a pre-determined pressure setting.
Usage Guideline:
Local codes may require limiting the heating head pressure in the vapor line in some applications.
5.
Snow Stand
Coated wire rack which supports unit 18 in. above mounting pad to allow for drainage from unit base.
Usage Guideline:
Heat pump installations in heavy snowfall areas.
Heat pump installations in snowdrift locations.
Heat pump installations in areas of prolonged subfreezing temperatures.
All commercial installations.
6.
Solenoid Valve
An electrically operated shutoff valve to be installed at the outdoor unit and which stops and starts refrigerant flow in response to compressor operation in
the heating mode.
Usage Guideline:
Required in long-line applications. Refer to the Residential Split-System Long-Line Application Guideline.
7.
Support Feet
Four stick-on plastic feet which raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, mini-
mizing corrosion.
Usage Guideline:
Suggested in the following applications:
Coastal installations.
Windy areas or where debris is normally circulating.
Rooftop installations.
For improved sound ratings.
8.
Thermostatic Expansion Valve (TXV)-Bi-flow - 2-speed Puron
A modulating, flow-control valve that meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the
evaporator. Kit includes valve, adapter tubes, and external equalizer tube.
Note:
Puron variable speed fan coils and Puron furnace coils are factory supplied with balanced-port Puron TXV.
Usage Guideline:
A balanced-port TXV specifically designed for Puron refrigerant is required for all installations.
EVOLUTION™* CONTROLS
* When applied with Bryant’s Perfect Humidity™ series 355, 315 and FE Indoor Models.
** Must be installed in Dual-Fuel Evolution system applications.
ACCESSORY
DESCRIPTION
SYSTXBBUID01
Evolution Control Deluxe 7-Day Programmable (Wall-mounted system control.)
SYSTXBBUIZ01
Evolution Zone Control Deluxe Zoning 7-Day Programmable (Wall-mounted control for a multi-zone system.)
SYSTXBB4ZC01
Evolution 4-Zone Damper Module Control (Wall-mounted control for a four-zone system.)
SYSTXBBSMS01
Evolution Smart Sensor (Optional wall control used to monitor temperature and/or fan control in an
individual zone.)
SYSTXBBRRS01
Evolution Remote Room Sensor (Monitors temperature in an individual zone.)
SYSTXBBSAM01
Evolution System Access Module (Hardware for wireless access and control via phone or internet.)
SYSTXBBNIM01**
Evolution Network Interface Module (Connects Heat Recovery or Energy Recovery Ventilators or older two-
speed outdoor models to system.)
SYSTXXXBPU01
Back Plate for Evolution Control (Decorative wall plate.)