![Bryant 189BNV EVOLUTION Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/bryant/189bnv-evolution/189bnv-evolution_installation-instructions-manual_2822022025.webp)
25
Flash Code
Type
Amber LED Description
Reset
Time
Mode
Possible Causes
Actions
98
Local
HIGH TORQUE EVENT
(Event will cause stage
down and when stage is at
lowest level, will elevate to
fault code 99)
NA
Both
Refer to 99
Refer to 99
99
System
Malfunction
HIGH TORQUE LOCKOUT
(Elevated from fault code
98 when 98 occurs at low-
est stage)
2 hours
Both
Miswire
Check miswire of compressor leads at
terminals U,V,W
Both
Refrigerant over-
charge
Check refrigerant amount
Both
Outdoor Airflow too
low or off
Check ODU coil for clogging (ice or de-
bris) and clean if necessary; Troubleshoot
ODU fan motor and make sure it is work-
ing
Both
Expansion Device
Restriction
Troubleshoot TXV
Troubleshoot EXV