25
COMBINATION RATINGS CONTINUED
ARI Ref. No.
Model Number
Indoor Model
Furnace Model
Capacity
EER
SEER
907785
165ANA048---B
CSPH*4812A**+TDR
47500
11.70
13.50
3020874
165ANA048---B
CSPH*6012A**
313*AV048070
47500
11.70
13.50
3020875
165ANA048---B
CSPH*6012A**
313*AV048090
48000
12.20
14.50
3020876
165ANA048---B
CSPH*6012A**
313*AV060110
48000
12.50
15.00
3020877
165ANA048---B
CSPH*6012A**
313*AV060135
48000
12.20
14.50
913952
165ANA048---B
CSPH*6012A**
315(A,J)AV048090
47500
12.50
14.50
910324
165ANA048---B
CSPH*6012A**
315(A,J)AV060110
47500
12.50
14.50
912480
165ANA048---B
CSPH*6012A**
315(A,J)AV066135
47500
12.95
15.00
911990
165ANA048---B
CSPH*6012A**
315(A,J)AV066155
48000
13.00
15.00
3120992
165ANA048---B
CSPH*6012A**
353AAV048080
47000
12.00
14.00
3120993
165ANA048---B
CSPH*6012A**
353AAV060100
47000
12.20
14.50
3120994
165ANA048---B
CSPH*6012A**
353AAV060120
47000
12.20
14.50
1390355
165ANA048---B
CSPH*6012A**
355(A,C)AV060080
47500
12.50
14.50
1390369
165ANA048---B
CSPH*6012A**
355(A,C)AV060100
47500
12.50
14.50
1390379
165ANA048---B
CSPH*6012A**
355(A,C)AV060120
47500
12.50
14.50
909882
165ANA048---B
CSPH*6012A**+TDR
48000
12.00
14.00
1249658
165ANA048---B
FE4AN(B,F)005+UI
47500
12.95
15.00
1249733
165ANA048---B
FEUI
48000
13.00
15.50
1348240
165ANA048---B
FV4BN(B,F)005
47500
12.95
15.00
912256
165ANA048---B
FV4BNB006
48000
13.00
15.50
914130
165ANA048---B
FX4CN(B,F)048
48000
12.50
14.50
909656
165ANA048---B
FX4CN(B,F)060
48500
12.50
15.00
908935
165ANA048---B
FY4ANB060
48000
11.70
13.50
913428
165ANA048---B
FY4ANF048
47500
11.70
13.50
911774
165ANA060---B
†CAP**6024A**+TDR
58500
11.85
14.00
908215
165ANA060---B
CAP**6021A**
315(A,J)AV060110
58500
12.00
14.20
910506
165ANA060---B
CAP**6021A**
315(A,J)AV066135
58500
12.20
14.50
907421
165ANA060---B
CAP**6021A**
315(A,J)AV066155
58500
12.20
14.50
3120995
165ANA060---B
CAP**6021A**
353AAV060100
57500
12.00
14.00
909222
165ANA060---B
CAP**6021A**+TDR
58500
11.85
14.00
914376
165ANA060---B
CAP**6024A**
315(A,J)AV060110
58500
11.95
14.20
912672
165ANA060---B
CAP**6024A**
315(A,J)AV066135
58500
12.00
14.20
3120996
165ANA060---B
CAP**6024A**
353AAV060120
58000
12.00
14.00
913444
165ANA060---B
CNPH*6024A**
315(A,J)AV060110
58500
12.00
14.20
907971
165ANA060---B
CNPH*6024A**
315(A,J)AV066135
58500
12.00
14.20
913712
165ANA060---B
CNPH*6024A**
315(A,J)AV066155
58500
12.20
14.50
3120998
165ANA060---B
CNPH*6024A**
353AAV048080
57000
11.70
13.50
3120999
165ANA060---B
CNPH*6024A**
353AAV060100
57500
12.00
14.00
3121000
165ANA060---B
CNPH*6024A**
353AAV060120
58000
12.00
14.00
908007
165ANA060---B
CNPH*6024A**+TDR
58500
11.85
14.00
908251
165ANA060---B
CNPV*6024A**
315(A,J)AV066135
58500
12.00
14.20
912248
165ANA060---B
CNPV*6024A**
315(A,J)AV066155
58500
12.20
14.50
3120997
165ANA060---B
CNPV*6024A**
353AAV060120
58000
12.00
14.00
1158804
165ANA060---B
CNPV*6024A**
368RAN060120
57500
11.50
14.00
909099
165ANA060---B
CNPV*6024A**+TDR
58500
11.85
14.00
907595
165ANA060---B
CSPH*6012A**
315(A,J)AV060110
58500
12.00
14.20
911022
165ANA060---B
CSPH*6012A**
315(A,J)AV066135
58500
12.20
14.50
910982
165ANA060---B
CSPH*6012A**
315(A,J)AV066155
58500
12.20
14.50
3121001
165ANA060---B
CSPH*6012A**
353AAV048080
57500
11.70
13.50
3121002
165ANA060---B
CSPH*6012A**
353AAV060100
58000
12.00
14.00
3121003
165ANA060---B
CSPH*6012A**
353AAV060120
58000
12.00
14.00
1390387
165ANA060---B
CSPH*6012A**
355(A,C)AV060120
58500
11.90
14.20
907965
165ANA060---B
CSPH*6012A**+TDR
58500
11.90
14.00
1249727
165ANA060---B
FEUI
59000
12.50
15.00
908985
165ANA060---B
FV4BNB006
59000
12.50
15.00
908649
165ANA060---B
FX4CN(B,F)060
58500
12.20
14.50
908129
165ANA060---B
FY4ANB060
59000
11.75
14.00
{
Tested combination
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other
combinations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are significantly affected.
EER
— Energy Efficiency Ratio
SEER
— Seasonal Energy Efficiency Ratio
TDR —
Time---Delay Relay. In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause
degradation in performance. Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are
equipped with TDR.
TXV
— Thermostatic Expansion Valve