APPLICATION CONSIDERATIONS

The Perfect Air Purifier is designed for use in the return air duct of
a forced air heating, cooling, and ventilation system. Models

GAPAAXBB1625

and

GAPAAXBB2025

are specifically

designed for use in systems with a forced air gas furnace.

Air Conditioning

The purifier should be installed in a system so that all the return air

is circulated through the air purifier. It should be located upstream
of both the furnace and the air conditioning evaporator coil. This

will help keep the furnace and evaporator coil clean and prevent
condensation from forming within the purifier.

Humidifiers

An evaporative humidifier can be mounted upstream of the

purifier. It is best to install atomizing humidifiers downstream of
the air purifier because hard water salt deposits and water droplets

may damage air purifier. If an atomizing humidifier must be
mounted upstream of the purifier, it should be mounted as far

upstream as possible (at least 6 ft./1.8 m recommended), and a

standard disposable furnace filter should be mounted between the
humidifier and the air purifier to trap hard water salt deposits and

water droplets.
Ensure that the humidifier installation will not allow water or water

droplets to enter the air purifier because it may cause electrical
arcing or damage the air purifier.

NOTE

: For fan coil installations, do not install the humidifier in

the fan coil access doors or cabinet.
Inspect for plugged drains and maintain humidifier drain lines on a
regular basis to avoid overflow of water into the air purifier. The

recommended inspection should be done at every change of the air
purifier cartridge (minimum, annually).

HIGH VOLTAGE HAZARD

Failure to follow this warning could result in personal injury

or death.
This air purifier utilizes high voltage. If you notice water

running into or around the air purifier, water stains on the

purifier cartridge or on the Enhancement Module walls or

cabinet, shut off the air purifier and call your service provider.

!

WARNING

Transitions

If the return air duct or furnace openings do not fit the purifier

cabinet openings, gradual transitions are recommended to reduce
air turbulence and maximize efficiency. No more than 45

_

(about

8.5 in. per running ft.) of expansion should be used on each side of
the transition fitting.

Turning Vanes

If the purifier is installed adjacent to a 90

_

duct elbow, turning

vanes should be added inside duct to improve air distribution
across the face of the air purifier.

Electrical Power

The purifier should only be powered when airflow is present. The
furnace control EAC terminals provide power only when the

furnace blower is operating. Perfect Air Purifier models
GAPAAXBB1625 and GAPAAXBB2025 are designed to be

powered from the electronic air cleaner (EAC) terminals on a

furnace electronic control. If EAC terminals are not available, an
alternative airflow sensing mechanism must be used to ensure the

purifier is only powered when airflow is present. Contact local
Bryant distributor for information on approved alternatives.

Door (x1)

Cabinet (x1)

Enhancement Module (x1)

Safety Screen (x1)

Installation Manual

Duct Gasket Tape

(1 roll)

Furnace Adapters (x2)

Return Duct Adapters:
Long (x2) / Short (x2)

Air Purification Cartridge (x1)

(x2)

(x2)

(x1)

(x1)

(x2)

Installation Components

(in bag attached to power cord)

A06064

Fig. 2 -- Perfect Air Purifier Components

GAP

A

A

Содержание 1625

Страница 1: ... les risques de choc electrique et A06054 Fig 1 GAPAA UNIT SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause explosion fire electrical shock or other conditions which may cause death personal injury or property damage Consult a qualified installer service agency or your distributor or branch for information or assistance The qualified installer ...

Страница 2: ...ion should be done at every change of the air purifier cartridge minimum annually HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death This air purifier utilizes high voltage If you notice water running into or around the air purifier water stains on the purifier cartridge or on the Enhancement Module walls or cabinet shut off the air purifier and call your s...

Страница 3: ...ifier should be readily accessible Enough room should be provided for periodic replacement of the air purifier cartridges ELECTRIC SHOCK AND UNIT DAMAGE HAZARD Failure to follow this warning could result in personal injury or death Only a trained experienced service person should install the purifier A thorough check of the unit installation should be completed before unit operation Before perform...

Страница 4: ...low Furnace Note When transitioning between two different sized components furnace purfier the minimum transition angle at the larger of the two components must be no less than 45 degrees A09022 Fig 4 Perfect Air Purifier Cabinet Orientation with Transition Furnace Adapters x2 Return Duct Adapters x4 Return Duct Furnace Adapters x2 Return Duct Adapters x4 Return Duct Top Mount Bottom Mount Side Mo...

Страница 5: ...d be used to connect the upstream side of the air purifier cabinet to the return air duct see Fig 7 g Install foam tape between the furnace and the air purifier cabinet h Mounting holes are provided for ductwork and furnace at tachment Note Slip S cleats onto flanges on air return duct side A05277 Fig 7 Use of Return Duct Adapters UNIT DAMAGE HAZARD Failure to follow this caution may result in uni...

Страница 6: ...r supply e Attach the quick connect terminals to the furnace EAC 1 and EAC 2 spade connections Attach the ground ring to furnace chassis ground NOTE The purifier is to be powered by 115v 60 Hz NOTE The purifier should only be powered when airflow is present The furnace control EAC spade connections provide power only when the furnace blower is operating If EAC connections are not available an alte...

Страница 7: ...he off position Remove the purifier door Slide out the old air purifier cartridge and discard Install the new air purifier cartridge Make sure the power cord is flexed out of the way to avoid damage to the air purifier cartridge pleats during insertion NOTE Verify that the air purifier cartridge is installed correctly Make sure that the arrows on the air purifier cartridge point toward the fan coi...

Страница 8: ...E SHARP BE VERY CAREFUL DURING CLEANING Tip of point with residue Tip of point after cleaning A06671 Fig 11 Removal of Deposits from Ionization Pins TROUBLESHOOTING SAFETY HAZARD Failure to follow this caution may result in personal injury or equipment damage The following instructions are for use by qualified personnel only CAUTION ELECTRICAL SHOCK HAZARD Failure to follow this warning could resu...

Страница 9: ...o cabinet cartridge to cabinet on the leaving air side are securely in place and making clean contact S Arcing to ground such as unit cabinet is occurring S Make sure the safety screen is clear and remove debris S Arcing to ground is occurring due to debris lodged in the safety screen or across ionization grid S Make sure the ionization grid is secured in place with all four clips and centered in ...

Страница 10: ...FM 1600 2000 Efficiency MERV 15 MERV 15 Replacement Cartridge GAPCCCAR1625 GAPCCCAR2025 Pressure Drop Maximum Airflow 25 InH20 25 InH20 Dimensions GAPAAXBB1625 GAPAAXBB2025 A 18 3 8 in 466 7mm 21 7 8 in 555 6mm B 15 1 8 in 384 1mm 18 5 8 in 473 1mm C 11 1 8 in 282 6mm 11 1 8 in 282 6mm D 17 1 2 in 444 5mm 21 in 533 4mm E 22 1 8 in 562mm 22 1 8 in 562mm F 25 1 4 in 642 4mm 25 1 4 in 642 4mm 7 16 11...

Страница 11: ...s and exclusions listed below and on the reverse if any of this document OWNER OCCUPIED RESIDENTIAL APPLICATIONS This warranty is to the original purchasing owner and is transferable only to the extent and as stated in the Warranty Conditions and below The warranty period in years depending on the part and the claimant is as shown in the chart below Limited Warranty Years Product Original Owner Su...

Страница 12: ...IMPLIED WARRANTY OR CONDITION LASTS SO THE ABOVE MAY NOT APPLY TO YOU THE EXPRESS WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED ENLARGED OR CHANGED BY ANY DISTRIBUTOR DEALER OR OTHER PERSON WHATSOEVER THIS WARRANTY DOES NOT COVER 1 Labor or other costs incurred for diagnosing repairing removing installing shipping servicing or handling of either defective parts or replaceme...

Отзывы: