background image

GAPAA

PERFECT AIR

t

PURIFIER

SIZES 1625 AND 2025

Installation Instructions

NOTE

: Read the entire instruction manual before starting the

install.

TABLE OF CONTENTS

PAGE

INTRODUCTION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

HOW IT WORKS

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . . .

APPLICATION CONSIDERATIONS

2

. . . . . . . . . . . . . . . . . . . .

INSTALLATION

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

START--UP AND OPERATION

6

. . . . . . . . . . . . . . . . . . . . . . . .

MAINTENANCE

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TROUBLESHOOTING

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SPECIFICATIONS AND DIMENSIONS

10

. . . . . . . . . . . . . . . .

WARRANTY

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

Congratulations for selecting the Perfect Air Purifier for your home
comfort system! The Perfect Air Purifier is proven to remove and

kill airborne germs and allergens, including viruses, bacteria, and
mold spores. The Perfect Air Purifier is a cornerstone of Bryant

Healthy Home Solutions for providing healthier, cleaner air in your

home.

HOW IT WORKS

The Perfect Air Purifier provides extremely high filtration

performance while killing captured contaminants, including
viruses, bacteria, and mold spores. The purifier treats the entire

air--stream through a state of the art, three--stage process.
In stage one, the particles are electrically charged by a

precision--point ionization array as they enter the purifier.
In stage two, the charged particles are electrically attracted to the air
purification cartridge, which is located within an electric field.
In stage three, captured particles are killed by electrical current
flow and ion bombardment.
The purifier is CSA certified for shock and electrical fire hazard

only.
La purifier certification CSA vise uniquement les risques de choc

electrique et.

A06054

Fig. 1 -- GAPAA UNIT

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,

or use can cause explosion, fire, electrical shock, or other

conditions which may cause death, personal injury or property
damage. Consult a qualified installer, service agency or your

distributor or branch for information or assistance. The qualified
installer or agency must use factory--authorized kits or accessories

when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,

and work gloves. Have a fire extinguisher available. Read these
instructions thoroughly and follow all warnings and cautions

included in literature and attached to the unit. Consult local
building codes and the current edition of the National Electrical

Code (NEC) NFPA 70.
In Canada, refer to the current editions of the Canadian Electrical
Code CSA C22.1.

Recognize safety information. When you see this symbol

on

the unit and in instructions or manuals, be alert to the potential for
personal injury. Understand the signal words

DANGER

,

WARNING

, and

CAUTION

. These words are used with the

safety--alert symbol.

DANGER

identifies the most serious hazards,

which

will

result in severe personal injury or death.

WARNING

signifies hazards, which

could

result in personal injury or death.

CAUTION

is used to identify unsafe practices, which

may

result

in minor personal injury or product and property damage.

NOTE

is used to highlight suggestions which

will

result in enhanced

installation, reliability, or operation.

Содержание 1625

Страница 1: ... les risques de choc electrique et A06054 Fig 1 GAPAA UNIT SAFETY CONSIDERATIONS Improper installation adjustment alteration service maintenance or use can cause explosion fire electrical shock or other conditions which may cause death personal injury or property damage Consult a qualified installer service agency or your distributor or branch for information or assistance The qualified installer ...

Страница 2: ...ion should be done at every change of the air purifier cartridge minimum annually HIGH VOLTAGE HAZARD Failure to follow this warning could result in personal injury or death This air purifier utilizes high voltage If you notice water running into or around the air purifier water stains on the purifier cartridge or on the Enhancement Module walls or cabinet shut off the air purifier and call your s...

Страница 3: ...ifier should be readily accessible Enough room should be provided for periodic replacement of the air purifier cartridges ELECTRIC SHOCK AND UNIT DAMAGE HAZARD Failure to follow this warning could result in personal injury or death Only a trained experienced service person should install the purifier A thorough check of the unit installation should be completed before unit operation Before perform...

Страница 4: ...low Furnace Note When transitioning between two different sized components furnace purfier the minimum transition angle at the larger of the two components must be no less than 45 degrees A09022 Fig 4 Perfect Air Purifier Cabinet Orientation with Transition Furnace Adapters x2 Return Duct Adapters x4 Return Duct Furnace Adapters x2 Return Duct Adapters x4 Return Duct Top Mount Bottom Mount Side Mo...

Страница 5: ...d be used to connect the upstream side of the air purifier cabinet to the return air duct see Fig 7 g Install foam tape between the furnace and the air purifier cabinet h Mounting holes are provided for ductwork and furnace at tachment Note Slip S cleats onto flanges on air return duct side A05277 Fig 7 Use of Return Duct Adapters UNIT DAMAGE HAZARD Failure to follow this caution may result in uni...

Страница 6: ...r supply e Attach the quick connect terminals to the furnace EAC 1 and EAC 2 spade connections Attach the ground ring to furnace chassis ground NOTE The purifier is to be powered by 115v 60 Hz NOTE The purifier should only be powered when airflow is present The furnace control EAC spade connections provide power only when the furnace blower is operating If EAC connections are not available an alte...

Страница 7: ...he off position Remove the purifier door Slide out the old air purifier cartridge and discard Install the new air purifier cartridge Make sure the power cord is flexed out of the way to avoid damage to the air purifier cartridge pleats during insertion NOTE Verify that the air purifier cartridge is installed correctly Make sure that the arrows on the air purifier cartridge point toward the fan coi...

Страница 8: ...E SHARP BE VERY CAREFUL DURING CLEANING Tip of point with residue Tip of point after cleaning A06671 Fig 11 Removal of Deposits from Ionization Pins TROUBLESHOOTING SAFETY HAZARD Failure to follow this caution may result in personal injury or equipment damage The following instructions are for use by qualified personnel only CAUTION ELECTRICAL SHOCK HAZARD Failure to follow this warning could resu...

Страница 9: ...o cabinet cartridge to cabinet on the leaving air side are securely in place and making clean contact S Arcing to ground such as unit cabinet is occurring S Make sure the safety screen is clear and remove debris S Arcing to ground is occurring due to debris lodged in the safety screen or across ionization grid S Make sure the ionization grid is secured in place with all four clips and centered in ...

Страница 10: ...FM 1600 2000 Efficiency MERV 15 MERV 15 Replacement Cartridge GAPCCCAR1625 GAPCCCAR2025 Pressure Drop Maximum Airflow 25 InH20 25 InH20 Dimensions GAPAAXBB1625 GAPAAXBB2025 A 18 3 8 in 466 7mm 21 7 8 in 555 6mm B 15 1 8 in 384 1mm 18 5 8 in 473 1mm C 11 1 8 in 282 6mm 11 1 8 in 282 6mm D 17 1 2 in 444 5mm 21 in 533 4mm E 22 1 8 in 562mm 22 1 8 in 562mm F 25 1 4 in 642 4mm 25 1 4 in 642 4mm 7 16 11...

Страница 11: ...s and exclusions listed below and on the reverse if any of this document OWNER OCCUPIED RESIDENTIAL APPLICATIONS This warranty is to the original purchasing owner and is transferable only to the extent and as stated in the Warranty Conditions and below The warranty period in years depending on the part and the claimant is as shown in the chart below Limited Warranty Years Product Original Owner Su...

Страница 12: ...IMPLIED WARRANTY OR CONDITION LASTS SO THE ABOVE MAY NOT APPLY TO YOU THE EXPRESS WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED ENLARGED OR CHANGED BY ANY DISTRIBUTOR DEALER OR OTHER PERSON WHATSOEVER THIS WARRANTY DOES NOT COVER 1 Labor or other costs incurred for diagnosing repairing removing installing shipping servicing or handling of either defective parts or replaceme...

Отзывы: