background image

Disposal.

When you plan to dispose of
the device, please return to
Bryant Dental

®

 for recycling. The

European Union Waste Electrical
and Electronic Equipment
(WEEE) Directive forbids the
disposal of waste electrical and
electronic equipment as unsorted
municipal waste, requiring that
it be collected and recycled or
disposed of separately.

www.bryant.dental

  |

  17

Hazardous substances are present in electrical
and electronic equipment and present potential
risk to human health and the environment if
disposed of in municipal and fills, which are not
designed to prevent migration of substances
into the soil and groundwater.. 

Ignis Gesture

 battery packs contain Lithium

Ion cells. Return to Bryant Medical, recycle or
dispose of the batteries according to national,
state, and local regulations.
 
Compliant with RoHS directive 2011/65/EU.

UK +44 (0)7990 113723 

|

 AUS +61 (02) 44838 35021

Содержание 5060678494322

Страница 1: ...Ignis Gesture ...

Страница 2: ...Illumination reimagined ...

Страница 3: ... instructions 12 Components 14 Charging and before use 15 How to use 16 Cleaning and maintenance 17 Disposal 18 Servicing and troubleshooting 19 Get in touch 20 Warranty 21 Technical specifications Contents www bryant dental 03 UK 44 0 7990 113723 AUS 61 02 44838 35021 ...

Страница 4: ...04 www bryant dental The BD story UK 44 0 1932 320064 AUS 61 02 72089592 ...

Страница 5: ...passionate talented dentists who believe like us that dentistry can be done differently Inspired by clinicians who strive for brilliance we aim to bring the latest innovation and technology to extraordinary dentists to facilitate their pursuit of excellence Dr Connor Bryant CEO and Founder www bryant dental 05 UK 44 0 7990 113723 AUS 61 02 44838 35021 Dr Priyam Patel Co CEO MagStrap Lucidum C Flo ...

Страница 6: ...06 www bryant dental UK 44 0 1932 320064 AUS 61 02 72089592 ...

Страница 7: ...Gesture was created to provide an ultra bright headlight with outstanding optical clarity Ultra light and bright the Ignis Gesture re imagines surgical and dental illumination whilst making your loupes feel lighter UK 44 0 7990 113723 AUS 61 02 44838 35021 ...

Страница 8: ...tential burn Do not look directly into the light output The Ignis Gesture Headlight is an illumination device attached to spectacles that is intended to illuminate oral structures and operating areas This device is designed to be used by qualified dental professionals including but not limited to dentists and dental hygienists as well as medical doctors and or professionals Ignis Gesture must be u...

Страница 9: ...lieve in creating excellent products for extraordinary dentists and we are always proud to gain a new member of our community of passionate clinicians Join the BD club to see what other members have done with Ignis Gesture www bryant dental 09 ...

Страница 10: ... components without authorisation from Bryant Dental Do not leave the light on inside a pocket as it will cause the unit to overheat Do not leave the battery or the headlight on exposed skin as it can cause burns Do not charge unattended or leave in environments exceeding 40 C If battery behaves abnormally immediately contact Bryant Dental Take care not to touch the LED during use as this can caus...

Страница 11: ......

Страница 12: ...nts UK 44 0 1932 320064 AUS 61 02 72089592 Headlight bracket frame specific Ignis Gesture Magstrap Ignis Gesture screwdriver Quick start guide LED Headlight Dichroic composite filter Battery unit x2 Power adapter country specific ...

Страница 13: ......

Страница 14: ...the power supply and the power adapter is plugged into the wall plug and switched on Switch ON There are two LEDs on the charging plate which glow blue when the batteries are charging and glow green when fully charged The LED on the left shows the charging status of the top battery and the right LED indicates the charging status of the bottom battery Charging status UK 44 0 1932 320064 AUS 61 02 7...

Страница 15: ...R sensor window located on the left arm of your loupes for 2 4 seconds to switch on the Ignis Gesture 4 To switch between low and high brightness levels briefly move your hand past the sensor window 5 To switch off the Ignis Gesture bring your hand up to the sensor window on the left once more until the light turns off UK 44 0 7990 113723 AUS 61 02 44838 35021 Approx 2 5cm away from sensor On Appr...

Страница 16: ...ot submerge in any liquid or ultrasonic cleaner Do not spray the device Do not use autoclave or chemiclave Do not use glutaraldehyde or idophor Do not use a cleaner with alcohol concentration greater than 70 16 www bryant dental UK 44 0 1932 320064 AUS 61 02 72089592 ...

Страница 17: ...ly www bryant dental 17 Hazardous substances are present in electrical and electronic equipment and present potential risk to human health and the environment if disposed of in municipal and fills which are not designed to prevent migration of substances into the soil and groundwater Ignis Gesture battery packs contain Lithium Ion cells Return to Bryant Medical recycle or dispose of the batteries ...

Страница 18: ...nt Dental Ignis Gesture is not switching on Run through userguide to ensure correct operation Run through troubleshooting guides If unsuccessful contact Bryant Dental Light comes on intermittently Ensure Ignis Gesture battery pack has charge Ensure all connections are clean Ensure wires are not twisted Light is flickering Ensure Ignis Gesture battery pack has charge Ensure all connections are clea...

Страница 19: ... direct WhatsApp link you can find on the support page of our website at www bryant dental support Our office team is also available to answer any questions you may have Scan to connect 61 02 4838 35021 44 0 7990 113723 61 02 72089592 UK office address The Barns Hilltop Farm Lyne Lane Chertsey KT16 0AW United Kingdom Australian office contact number Australian Office Address Suite 18 13U 175 Lower...

Страница 20: ...iod of two years without charge The liability will not exceed the amount you originally paid for the product The warranty does not cover defects arising from negligence product modification unauthorised repairs accidental damage theft loss or acts of God UK 44 0 1932 320064 AUS 61 02 72089592 See Product SN 5060678494322 GTIN ...

Страница 21: ...42 mm 26 mm 26mm Ignis LED Headlight with integrated headstrap Dichroic wavelength filter x2 Ignis Gesture batteries Quick start guide Instruction manual can be downloaded Battery charging dock Ignis USB wall plug country specific Ignis screw driver Ignis bracket UK 44 0 7990 113723 AUS 61 02 44838 35021 35 5 mm ...

Страница 22: ...r 40cm Working Distance Beam colour temperature 5700K Beam intensity 36 90 lumens Battery weight Circa 33g each System weight Circa exc batteries 62g Battery operating power DC3 8V 450mA 4 71Wh Charger input AC100 240 volts 50 60 Hz max 0 8A Charger output 5 0V 2A 10W Operating time constant output 2 5 hours Battery charge discharge cycle count 300 Operating temperature 0 30 C Charging temperature...

Страница 23: ... MDR Operating temperature limit 100 C 300 C Bryant Medical Ltd The Barns Hilltop Farm Lyne Lane Chertsey KT16 0AW U K www bryant dental 23 EN60601 1 2006 A1 2013 EN60601 1 2 2015 A1 2021 IEC60601 1 6 2010 A1 2013 A2 2020 IEC60601 1 2 2014 A1 2020 EN60601 1 2006 A12 2014 IEC62471 2006 risk group 2 Meets requirements of the EU MDR UK 44 0 7990 113723 AUS 61 02 44838 35021 Keep the device a minimum ...

Страница 24: ...a Bryant Medical The Barns Hilltop Farm Lyne Lane Chertsey KT16 0AW UK Registered in England Wales No 10396020 Registered in Australia No 634 752 980 www bryant dental UK 44 0 7990 113723 AUS 61 02 4838 35021 UK 44 0 1932 320064 AUS 61 02 72089592 BR15 EN1 0 IGG IFU Rev 1 6 May 2022 ...