![Bryan Mumford MicroSet Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/bryan-mumford/microset/microset_quick-start-manual_2821976032.webp)
Page 32
Beat Error Mode - measure beat error
Press BEGIN to start measuring. The number of milliseconds of beat error will be
shown.
Time Mode - measure the rate a watch
Press PLUS or MINUS to set the number of beats to measure.
Press BEGIN to start measuring.
Blanking Window - to make the timer immune to other sounds
To maximize it, hold PLUS until the LED stays on.
To minimize it, hold MINUS until the LED stays off.
You can adjust the default setting of OFF with the Configuration Mode.
Time Mode Options
Press BEGIN to access the options available in your timer.
Show error/day: Press PLUS to enter the correct rate of the timepiece or press
MINUS to disengage Error Per Day calculation. MicroSet will guess the correct
Target Rate. If it’s right, press BEGIN. If it’s not right, press MINUS to display
the last value measured, then press PLUS or MINUS to adjust it.
Average On/Off
: Press PLUS to turn it on, MINUS to turn it off
Speaker On/Off: Press PLUS to turn it on, MINUS to turn it off
Data Capture: Press PLUS to begin data capture. The number shown will be
the number of readings taken before one is saved. Set the number to zero to
stop capture.
Dump: Press PLUS to dump the captured data to a personal computer.
Paper tape: Press PLUS to begin paper tape output. After the current rate is
shown, press PLUS or MINUS to adjust it. Select the correct rate for a rate
reading, or just accept the current rate for a flat tape. Press BEGIN to start
printing. Press PLUS to zoom in, MINUS to zoom out. Press BEGIN to restart
a reading at the center of the tape. Press MODE to terminate paper tape
printing.
Accutron Mode - show the rate of tuning fork watches
Press BEGIN and select the number of “blocks” to measure (the time before a
reading appears).
Press BEGIN to start measuring.
Press PLUS to see the rate as Error Per Day.
Press MINUS to see the rate as frequency of the fork.
Tick Mode - send information about watch ticks to a PC
Press BEGIN to start sending tick data to the PC.
Balance Wheel Amplitude Mode - measure balance wheel amplitude with a PC
(optional)
Press BEGIN to start sending data to the PC.
Configuration Mode - to set various parameters of operation
Hold down NODE when you turn on the timer to enter the Configuration Mode.
Beep: Press PLUS to turn the beeper ON, press MINUS to turn it OFF.
Time beats
: Press PLUS or MINUS to set the default number of beats for the Time
Mode.
Blanking
: Press PLUS or MINUS to set the value of the Blanking Window when it
is turned off. Use 8 for most cases. Use 5 if you measure fast beat watches.
Units
: Press PLUS to see rates as Seconds Per Day, press MINUS to see rates as
Beats Per Hour.
Trim
: Oscillator calibration. Do not change this. Press MODE to exit.
Summary of Operations