Bryan Boilers HE-CLM Series Скачать руководство пользователя страница 2

Bryan HE-CLM Series Gas Fired Flexible Tube Boilers

Form No. 6700 

©2007 Bryan Steam LLC 

 Printed in USA

 

 

57-8782

Effi cient Water Tube Design

The Bryan Flexible Water Tube provides for extremely fast 
internal circulation for maximum heat transfer and operating 
effi ciency.

No “Thermal Shock”

The fl exibility of the bent water tube design eliminates all 
possible damage from “Thermal Shock” and from stresses 
caused by poor or unequal internal circulation. This is particu-
larly important with forced hot water heating systems designed 
for higher temperatures and greater temperature drops.

Natural Internal Circulation

The water tube design and the large water leg downcomers 
provide adequate internal circulation without concern over ex-
terior pumping conditions. Low pressure drop through boiler.

Compact — Minimum Floor Space

Requires less fl oor space than most boilers — minimum 
boiler room size.

Shipped completely assembled and wired.

Tubes are easily removable and replaceable, requiring little 
service space.

Combination  thermometer  and pres-
sure gauge, ASME-rated boiler relief 
valve, water temperature control (240°F 
max. std.), high  limit  control, probe 
LWCO.

 

Electronic combustion  safety 

control, automatic operating  gas valve, 
safety gas valve, pilot  solenoid  valve, 
pilot  ignition  assembly, main  manual 
gas shut-off valve, pilot cock, pilot 
and main  gas pressure  regulators, air 
safety switch, control panel, all controls 
installed  and  wired.

Dimensions and specifi cations are subject to change without notice. Consult factory for certifi ed dimensions.

Bryan Steam LLC 

 Leaders

 

Since 1916

  

783 N. Chili Ave., Peru, Indiana 46970 U.S.A.
Phone: 765-473-6651 • Internet:www.bryanboilers.com  
Fax: 765-473-3074  • E-mail: [email protected]

OPTIONAL CONSTRUCTION:

Optional construction to ASME Power 
Boiler Code requirements for tempera-
tures exceeding  240°F  and/or  pres-
sure exceeding 160 psi to maximum 
of 285°F operating and 300°F design 
temperature and 250 psi.

When ordering, please specify:

1. Boiler 

size

2. Supply 

and 

return 

 temperatures 

required

3.  Boiler relief valve setting
4.  Type of fuel: natural, LP,
 

 or other gas

5.  Gas BTU content, specifi c 

gravity and pressure 

 available
6. Electric 

power 

voltage, 

 

phase and frequency

7.  Optional extra equipment 
 or 

construction

8. Special 

approvals 

required 

(UL, CUL, CSD-1, FM, or IRI)

9. Altitude

OPTIONAL EQUIPMENT:

1.  Manual reset high limit control
2.  Manual reset low water cutoff
3.  Auxiliary low water cutoff
4.  Combination low water cutoff 
 and 

feeder

5.  Alarm bells or horns
6.  UL, CUL, CSD-1, FM, IRI or other in-

surance approved control systems

7.  Control panel mounted on boiler
8.  Indicating lights, as desired
9.  Lead-lag systems for two or more 

boilers with or without outdoor 

 reset 

control

 

STANDARD EQUIPMENT:

Bryan HE-CLM Series Boilers Standard and Optional Equipment

10. Draft control system
11. Special construction
 

and knocked down

NOTE:  *

 

Gas train and control location dimensions will vary depending on job specifi cations and conditions.

BOILER DIMENSIONS in inches (cm)

 

 A 

  D 

   E* 

F     

 G 

 I 

 J 

L

    BOILER 

Length 

Width 

Height 

 

Overall 

 Gas Train 

Supply   Return 

Flue 

Flue

 Min. 

Tube 

Clearance 

for 

Floor 

to 

    MODEL 

Of 

Outside 

Over 

 

Length  

Connection  Nozzle  Nozzle  Size  Location

 Removal 

Servicing 

Flow

   NUMBER 

Jacket 

Jacket 

Jacket 

 

 

 

 

  

  

Clearance 

Burner 

Nozzle

HE-CLM90-W

  

41 

7

/

16 

34 

5

/

72 

1

/

16

 69  

7

/

16

 

1 NPT 

3 NPT 

3 NPT 

10

 

20 

11

/

16 

30 36

 

76 

3

/

16

 

(105.24) (87.94) (180.03) 

(176.98)  (2.54) 

(7.62)  (7.62) (25.40) (52.54)  (76.2) 

(91.44)  (193.51)

HE-CLM120-W

  

50 

11

/

16 

34 

5

/

72 

1

/

16

 78 

11

/

16

 

 1

1

/

 NPT 

3 NPT 

3 NPT 

10

 

25 

5

/

16 

30 36

 

76 

3

/

16

 

(128.74) (87.94) (180.03) 

(199.86)  (3.18) 

(7.62)  (7.62) (25.40) (64.29)  (76.2) 

(91.44)  (193.51)

HE-CLM150-W

  

59 

11

/

16 

34 

5

/

72 

1

/

16

 87 

11

/

16

 

 1

1

/

 NPT 

3 NPT 

3 NPT 

12

 

29 

13

/

16 

30 36

 

76 

3

/

16

 

(151.60) (87.94) (180.03) 

(212.72)  (3.81) 

(7.62)  (7.62) (30.48) (75.72)  (76.2) 

(91.44)  (193.51)

HE-CLM180-W

 69 

1

/

34 

5

/

72 

1

/

16

 97 

1

/

8

 

2

 

 NPT 

3 NPT 

3 NPT 

14

 

34 

9

/

16 

30 36

 

76 

3

/

16

 

(175.57) (87.94) (180.03) 

(246.69)  (5.08) 

(7.62)  (7.62) (35.56) (87.78)  (76.2) 

(91.44)  (193.51)

HE-CLM210-W

 78 

3

/

34 

5

/

72 

1

/

16

 106 

3

/

8

 

2 NPT 

3 NPT 

3 NPT 

14

 

39 

3

/

16 

30 36

 

76 

3

/

16

 

(199.07) (87.94) (180.03) 

(270.19)  (5.08) 

(7.62)  (7.62) (35.56) (99.53)  (76.2) 

(91.44)  (193.51)

HE-CLM240-W

 88

 

34 

5

/

72 

1

/

16

 

116 

2 NPT 

3 NPT 

3 NPT 

16

 

44

 

30 36

 

76 

3

/

16

 

(223.52) (87.94) (180.03) 

(294.64)  (5.08) 

(7.62)  (7.62) (40.64) 

(111.76)  (76.2) 

(91.44)  (193.51)

HE-CLM270-W

 97

 

34 

5

/

72 

1

/

16

 

125 

2 NPT 

3 NPT 

3 NPT 

16

 

48

1

/

30 36

 

76 

3

/

16

 

(246.38) (87.94) (180.03) 

(317.50)  (5.08) 

(7.62)  (7.62) (40.64) 

(123.19)  (76.2) 

(91.44)  (193.51)

HE-CLM300-W

 106 

5

/

34 

5

/

72 

1

/

16

 134  

5

/

8

 2 

1

/

 NPT 

3 NPT 

3 NPT 

16

 

53 

3

/

16 

30 36

 

76 

3

/

16

 

(270.82) (87.94) (180.03) 

(341.91)  (6.35) 

(7.62)  (7.62) (40.64) (40.64)  (76.2) 

(91.44)  (193.51)

Отзывы: