Technical data
and start-up
BDC546
12
3.3.3
Safety instructions for handling and operation
NOTICE
Damage to the DC/DC converter:
As a rule, it is to be ensured that the voltage ranges of all devices connected to the DC/DC
converter are identical.
Only use technically suitable and high-quality cables!
A high cooling water temperature and/or ambient temperature reduces the life span! Therefore,
ensure that the device is continuously cooled sufficiently!
Do not place the device in direct sunlight and in direct proximity to heat sources!
Even though the device has a high IP protection class, direct contact with water (rain, splashing
water) is to be avoided if possible!
Never damage existing galvanic isolations (e.g. by connecting HV contacts with the device
casing) in the vehicle.
Prevent any fluid ingress into the device (e.g. during assembly work). Fluid ingress will lead to a
short circuit and subsequently to damage to the device!
In the case of any fluid ingress, do not start the device and immediately contact BRUSA
Elektronik AG!
Always use an isolation monitoring unit to continuously monitor the galvanic isolation between
the HV and LV circuit!
Never connect or disconnect the HV connectors without ensuring the absence of voltage
beforehand!
Before connecting a voltage supply to the highside or lowside of the DC/DC converter (e.g.: HV
battery), the voltage must be pre-charged by means of a suitable pre-charging device. Refer to
chapter
INFORMATION
The device may be used up to a maximum altitude of 4,000 m above sea level!
Содержание BDC546
Страница 27: ...27 Technical data and start up BDC546 6 6 Vehicle installation basic principle ...
Страница 82: ...Technical data and start up BDC546 82 16 Attachments 16 1 Cable fitting ...
Страница 83: ...83 Technical data and start up BDC546 ...
Страница 84: ...Technical data and start up BDC546 84 ...
Страница 85: ...85 Technical data and start up BDC546 ...
Страница 86: ...Technical data and start up BDC546 86 16 2 Cable lugs ...
Страница 87: ...87 Technical data and start up BDC546 ...