background image

Chapter 1 — General Information

Safety

100 kHz Input Module Type 3016

Service Manual

BI 5035 –12e

1

3

1.3

Safety

Type 3016 has been designed and tested in accordance with IEC Publication 348,
Safety Requirements for Electronic Measuring Apparatus, and has been supplied in
safe condition.

Any work done on the instrument when open must be done by a qualified person
who is aware of the hazards involved.

Note: The word WARNING denotes a hazard. It calls attention to a procedure,
practice, or like, which, if not correctly performed or adhered to, could result in
personal injury.

1.4

Service Policy and FRP Number

Type 3016 is a Field Replaceable Part (FRP). To assure economical reuse, it is
important that no attempt is made to repair it locally. If such an attempt is made,
the price of an exchange FRP is 100% the price of a new one.

Therefore, DO NOT ATTEMPT ANY REPAIR to Type 3016. Order the module as
an FRP using order number FR 0002.

1.5

Special Tools and Equipment

Type 3016 must always be checked as part of a multichannel system incorpo-
rating Acquisition Front-end Type 2825 or Multichannel Data Acquisition Unit
Type 2816. No other special conditions exist.

Содержание 3016

Страница 1: ...el Kjær BI 5035 12e Technical Documentation WORLD HEADQUARTERS DK 2850 Nærum Denmark Telephone 4545800500 Telex 37316 bruka dk Fax 4545801405 e mail info bk dk 100 kHz Input Module Type 3016 Service Manual ...

Страница 2: ...0 2 Brüel Kjær 100 kHz Input Module Type 3016 Service Manual Proprietary Authorized Brüel Kjær Personnel Only ...

Страница 3: ...April 1997 BI 5035 12e Brüel Kjær 100 kHz Input Module Type 3016 Service Manual 100 kHz Input Module Type 3016 Service Manual Valid from serial number 1 566 580 ...

Страница 4: ...s product may cause radio interference in which case the user may be required to take adequate measures Switch off all power to equipment before connecting or disconnecting their digital interface Failure to do so could damage the equipment Whenever it is likely that the correct function or operating safety of the apparatus has been impaired it must be made inoperative and be secured against unint...

Страница 5: ...rvice Policy and FRP Number 1 3 1 5 Special Tools and Equipment 1 3 2 Service Note 2 1 2 1 On line Editions of the Service Manual 2 2 2 2 Printed Editions of the Service Manual 2 2 3 Checking Procedure 3 1 3 1 Introduction 3 2 3 2 Checking Procedure 3 2 Hardware Modification 3 2 Functionality 3 3 4 Mechanical Parts 4 1 4 1 Chassis Parts 4 2 4 2 Spare Parts 4 3 ...

Страница 6: ...100 kHz Input Module Type 3016 Service Manual Brüel Kjær 0 4 ...

Страница 7: ...100 kHz Input Module Type 3016 Service Manual BI5035 12e 1 1 Chapter 1 General Information ...

Страница 8: ...tioning of the input signal and finally an A D converter 1 2 Edition Number If any major changes are made to the instrument and or Service Manual a new edition of the Service Manual will be released Any new edition can be recognised by the Literature Number BI 5035 xx given at the bottom of odd numbered pages The serial number from which each edition is valid is printed in the Frontispiece of this...

Страница 9: ...actice or like which if not correctly performed or adhered to could result in personal injury 1 4 Service Policy and FRP Number Type 3016 is a Field Replaceable Part FRP To assure economical reuse it is important that no attempt is made to repair it locally If such an attempt is made the price of an exchange FRP is 100 the price of a new one Therefore DO NOT ATTEMPT ANY REPAIR to Type 3016 Order t...

Страница 10: ...100 kHz Input Module Type 3016 Service Manual Brüel Kjær 1 4 ...

Страница 11: ...100 kHz Input Module Type 3016 Service Manual BI 5035 12e 2 1 Chapter 2 Service Note ...

Страница 12: ...n of the on line source document This Service Note section contains a history of the changes when any are made 2 2 Printed Editions of the Service Manual From time to time some minor changes may be made to improve the performance and serviceability of Type 3016 All information concerning these changes or any other changes to the Service manual will be released in the form of a Service Note Note Pr...

Страница 13: ...100 kHz Input Module Type 3016 Service Manual BI 5035 12e 3 1 Chapter 3 Checking Procedure ...

Страница 14: ...r 1 Refer to Chapter 4 if there is mechanical damage to the module 3 2 Checking Procedure 3 2 1 Hardware Modification If a Signal Output Module Type 5955 module is used in the system input module Type 3016 needs to have a wiring change made to it to allow analogue signals to pass into Type 5955 from the backplane rather than the other way round 1 Check that the co axial cable is routed to J14 and ...

Страница 15: ...kHz Input Module Type 3016 Service Manual BI 5035 12e 3 3 3 2 2 Functionality Type 3016 can be tested using the BZ 5076 Analog Hardware Test Program or the test program that is part of the PULSE system refer to Chapter 5 of the PULSE Installation Manual ...

Страница 16: ...100 kHz Input Module Type 3016 Service Manual Brüel Kjær 3 4 ...

Страница 17: ...100 kHz Input Module Type 3016 Service Manual BI 5035 12e 4 1 Chapter 4 Mechanical Parts ...

Страница 18: ...ical Parts Chassis Parts 100 kHz Input Module Type 3016 Service Manual Brüel Kjær 4 2 4 1 Chassis Parts Fig 4 1 Exploded view of chassis parts 970158e Red lead Yellow lead Empty 8 9 9 8 6 5 7 4 2 3 1 Brüel Kjær B B B K ...

Страница 19: ...4 2 Spare Parts Item Part No Identification 1 ZN0482 UA1142 100 kHz Input Front Cover Set including Items 2 9 2 FA1087 Front Cover 3 GU1640 Distance Panel 4 YS9372 Retaining Screws 5 YM0334 Nut 6 YO0337 Washer 7 QV4056 LED with Leads 8 DH0274 House for Plug 9 XB0294 Code Tap Table 4 1 Spare parts list ...

Страница 20: ...100 kHz Input Module Type 3016 Service Manual Brüel Kjær 4 4 ...

Отзывы: