130
Troubleshooting Steps
Use a process of elimination to troubleshoot network problems.
1. If the LCD screen of the
ICON
gauge displays a value of zero (0) in any data field, it indicates the gauge is
not receiving a signal from one or more devices.
• Make sure the data sources are configured.
• If multiple data fields are displaying “0”, check common items such as cables and t-connectors.
• Remove components from the network
one at a time
to isolate failed components.
• Look for damaged parts.
• Check connectors for corrosion.
• Swap known good components (sensor, cables or t-connectors) to isolate the faulty component.
• Reconnect the good component to the network and the remove the next one in line.
• Continue this process for each device, cable or tee connector on the network until the faulty part is found.
NOTE:
After a component is reconnected to the network, cycle the key switch OFF and back ON to reset the
gauge(s).
Troubleshooting Steps
Use a process of elimination to troubleshoot network problems.
1. If the LCD screen of the
ICON
gauge displays a value of zero (0) in any data field, it indicates the gauge is
not receiving a signal from one or more devices.
• Make sure the data sources are configured.
• If multiple data fields are displaying “0”, check common items such as cables and t-connectors.
• Remove components from the network
one at a time
to isolate failed components.
• Look for damaged parts.
• Check connectors for corrosion.
• Swap known good components (sensor, cables or t-connectors) to isolate the faulty component.
• Reconnect the good component to the network and the remove the next one in line.
• Continue this process for each device, cable or tee connector on the network until the faulty part is found.
NOTE:
After a component is reconnected to the network, cycle the key switch OFF and back ON to reset the
gauge(s).
Содержание Evinrude E-TEC Icon Pro Series
Страница 1: ...ICON Pro Series Gauge User s Guide 766075 ICON Pro Series Gauge User s Guide P N 766075 Rev A Rev A ...
Страница 2: ......
Страница 7: ...ICON PRO SERIES Gauge Setup ...
Страница 32: ...30 ...
Страница 33: ...Tachometer Operation ...
Страница 109: ...Speedometer Operation ...
Страница 130: ...128 ...
Страница 131: ...Troubleshooting ...
Страница 139: ...Reference ...
Страница 145: ...143 Notes ...
Страница 146: ...Product Warranty ...
Страница 150: ...148 ...
Страница 152: ......
Страница 154: ......
Страница 155: ......
Страница 156: ...ICON Pro Series Gauge User s Guide 766075 ICON Pro Series Gauge User s Guide P N 766075 Rev A Rev A ...