Measurement Units
The meter can be set to measure % saturation, dissolved
oxygen in mg/l, and dissolved oxygen in parts per million
(ppm). To change the mode:
1. Press and hold the MODE/HOLD button for 2 seconds
and the display will begin to scroll through the different
units of measure : % saturation; D.O. in mg/l; D.O. in
ppm (parts per million)
2. When the desired units are displayed, release the
MODE/HOLD button and the unit will return to normal
operating mode.
Note
: The “HOLD” function cannot be on when changing
the measurement function. If “HOLD” is displayed in the
lower left corner of the display, briefly press the MODE/
HOLD button to turn it off.
Temperature Units (ºF/ºC)
1. With the unit OFF, press and hold the CAL/RECALL
button.
2. With the CAL/RECALL button depressed, momentarily
press the ON/OFF button to turn the unit ON.
3. The CAL/RECALL button can be released when ‘Self Cal’
is shown in the display.
Salinity Compensation
1. With the unit ON, momentarily press the CAL/RECALL
button twice in quick succession (‘SAL’ is shown in the
lower temperature display).
2. Momentary press the MODE/HOLD button. Each press
of the MODE/HOLD button increases the compensation
by 1ppt (part per thousand); the available range is 0 to
50ppt.
3. Momentarily press the CAL/RECALL button to save the
compensation setting and return to the normal mea-
surement mode.
Altitude Compensation
1. With the unit ON, momentarily press the CAL/RECALL
button twice in quick succession (‘SAL’ is shown in the
lower temperature display.
2. Press and hold CAL/RECALL again for 2 seconds to enter
the Altitude Mode (‘Ald’ will be shown in the lower tem-
perature display).
3. The factory default value is sea level. Each press of
the MODE/HOLD button increases the compensation
by 1000ft. The maximum value is 20 presses (20,000ft
above sea level).
4. Momentarily press the CAL/RECALL button to save the
compensation setting and return to the normal mea-
surement mode.
Auto-Power OFF Feature
The auto power off feature automatically shuts the meter
off 10 minutes after the most recent button press.
To disable this feature, refer to the Disable Auto-Power
OFF section.
Disable Auto-Power OFF Feature
With the unit ON, momentarily press the CAL/RECALL but-
ton, then quickly press and hold both the MODE/HOLD and
ON/OFF buttons until ‘off’ is displayed. To restore the Auto
Power Off Feature (auto power OFF enable) simply turn the
meter off and on again using the ON/OFF button.
Low Battery Indication
When the battery voltage falls below the operating thres-
hold, ‘BAT’ will appear on the display. Refer to the Mainte-
nance section for battery replacement information.
Storing Readings
1. Press the MODE/HOLD button to store a reading. The
storage location number will be displayed on the lower
display, while the main display shows the stored rea-
ding. The meter will enter the HOLD mode and the
“HOLD” indicator will appear on the LCD.
2. Press the MODE/HOLD button again to exit the HOLD
mode and return to normal operation. The next time
MODE/HOLD is momentarily pressed another reading is
stored and so on.
3. If more than 25 readings are stored, previously stored
readings (starting with reading number 1) are overwrit-
ten.
Recalling Stored Readings
1. Momentarily press the CAL/RECALL button and then
with in 4 seconds momentarily press the MODE/HOLD.
The last stored data point location will be displayed (1 to
25). Each time the MODE/HOLD button is momentarily
pressed the next most recently stored data point will be
displayed.
2. After the last data point stored is displayed, pressing
the MODE/HOLD button again returns the display to the
beginning of the list.
3. Pressing the CAL/RECALL button at anytime stops the
data retrieval process and returns the meter to the nor-
mal measurement mode.
Clearing Stored Readings
1. With the unit ON press and hold the ON/OFF button for
4 seconds
2. When “clr” is shown in the main display the memory is
cleared.