II - 5
2.1.5 Cover Open (Cover Lock) Sensor
The cover open (cover lock) sensor R (push switch) is mounted on the SB PCB
ASSY.
The cover open (cover lock) sensor L (push switch) is secured on the cutter unit
ASSY with the screw.
Closing the top cover ASSY, the cover sensor arms R and L push the cover open
(cover lock) sensors (R and L) (push switch) and the signal of top cover ASSY close
status is output.
Figure 2.1-5 Cover Open (Cover Lock) Sensor
Top cover ASSY
Rib
Cover sensor arm L
Cover open (cover lock)
sensor L (push switch)
Cover open (cover lock)
sensor L (push switch)
Top cover ASSY
Rib
Cover sensor arm L
Cutter unit ASSY
SB PCB ASSY
Top cover ASSY
Rib
Cover sensor arm R
Cover open (cover lock)
Sensor R (push switch)
Cover open (cover lock)
Sensor R (push switch)
SB PCB ASSY
Rib
Cover sensor arm R
Содержание TD-4000