13. LIST OF ERROR CODES
88
Code
Cause
Remedy
E190
Sewing machine motor was running continuously
for too long during sewing.
Turn the power off and then back on again.
E191
Thread trimming solenoid operation was not
completed within the specified period.
Turn off power and check if the thread trimming
mechanism is stiff.
Feed mechanism-related errors
Code
Cause
Remedy
E210
Feed motor origin is not detected when power is
turned on.
・
Turn off the power and check that the feed
mechanism is not abnormal.
・
Turn off the power and check the feed motor
connector and connector P4.
E211
Abnormal feed motor operation detected during
sewing.
・
Turn off the power and check that the feed
mechanism is not abnormal.
・
Turn off the power and check the feed motor
connector and connector P4.
E251
Abnormal feed motor overheating detected or feed
motor overheating sensor was not detected.
・
Turn off the power and check the sewing conditions.
・
Turn off the power and check the connection of
connector P4.
Communication and memory-related errors
Code
Cause
Remedy
E400
Panel connection was not detected when power
was turned on.
Turn off the power and check the connection of
connector P2.
E410
Communication error with panel occurred when
power was turned on.
Turn off the power and check the connection of
connector P2.
E422
Error when reading from USB media.
・
Press the Reset key.
・
Check the data in the USB media.
E424
Insufficient free space in USB media.
・
Press the Reset key.
・
Increase the amount of free space in the USB
media.
E425
Error when writing to USB media.
・
Press the Reset key.
・
Use the specified USB media.
E440
Data could not be written to the backup memory
(main internal P.C. board).
Turn the power off and then back on again.
E441
Data could not be read from the backup memory
(main internal P.C. board).
Turn the power off and then back on again.
E442
Back up memory (main internal P.C. board) data
was abnormal, so settings were initialized.
Turn the power off and then back on again.
E450
Model settings could not be read from machine
head memory (internal panel).
Turn the power off and then back on again.
E451
Data backup cannot be written to machine head
memory (internal panel).
Turn the power off and then back on again.