3-47
Confidential
9.23 Feed drive belt S / Feed drive belt / Feed motor
(1) Remove the feed drive belt S.
(2) Loosen the taptite cup S M3x6 screw.
(3) Remove the feed drive belt while pushing the tension pulley holder in the direction of the
arrow.
(4) Remove the two taptite cup S M3x6 screws to remove the feed motor.
Fig. 3-58
(5) Disconnect the feed motor harness from the feed motor.
(6) Remove the two gaskets from the feed motor.
Fig. 3-59
Feed drive belt S
Taptite cup S M3x6
Feed motor
Taptite cup S M3x6
Feed drive belt
Tension pulley holder
Feed motor
Feed motor harness
Gaskets