3-24
Confidential
<Attachment Procedure>
1) Attach the double-sided tape as shown in the figure below. (two places)
Fig. 3-24
2) Pass the first side CCD flat cable through the flat core “A”, and connect it to the main
PCB ASSY.
3) Fold the second side CCD flat cable within the red frame as necessary, pass it through
the flat core “B”, connect it to the main PCB ASSY, and attach it to the double-sided tape.
4) Connect the multi-feed sensor PCB flat cable (Receive) to the main PCB ASSY.
5) Attach the double-sided tape on the second side CCD flat cable as shown in the figure
below.
Fig. 3-25
Double-sided tapes
Second side CCD flat cable
Flat core “B”
Main PCB ASSY
Flat core “A”
Multi-feed sensor PCB flat cable (Receive)
First side CCD flat cable
Double-sided tape
Содержание PDS-5000
Страница 23: ...2 4 Confidential 2 2 Document Feed Path Fig 2 2 Front side Document feed path Back side ...
Страница 45: ...3 2 Confidential 2 PACKING Fig 3 1 ...
Страница 48: ...3 5 Confidential 5 LUBRICATION There are no parts that require lubrication ...
Страница 49: ...3 6 Confidential 6 OVERVIEW OF GEARS Left side Fig 3 3 Right side Fig 3 4 ...
Страница 63: ...3 20 Confidential 9 9 Back cover 1 Release the two hooks to remove the back cover Fig 3 18 Back cover Hooks ...
Страница 104: ...4 2 Confidential 6 OD MF Chart ASSY White paper Mech Chart OD Chart White A4 150g paper Crease paper A4 28g paper ...
Страница 106: ...4 4 Confidential 7 The window below appears on the screen Click the Information tab Scroll down and check F W Version ...
Страница 138: ...5 1 Confidential CHAPTER 5 SERVICE FUNCTIONS Service mode is not equipped with this product ...