2-38
Confidential
Error code 5800
Any of error codes 6A00 to 6F00, 7600, 7800, DD00, DE00, or E200 (fuser unit error)
occurred when the power switch was turned ON or sleep mode was released.
Error code 5900
Rechecking the error after the power switch was turned OFF and then ON again because an
error was detected by the center thermistor of the fuser unit.
(This message is displayed for approximately 15 minutes when the machine is restarted after
error code 5800 has occurred.)
Error codes 5A00 to 6200
These errors do not usually occur during normal use. The possible causes are noise around
the installation site, fluctuation of the power supply voltage, and failures in the software.
An unidentified error occurred.
Fuser Error
Turn the power off, then on again. Leave the machine for 15 min.
Self-Diagnostic
Will Automatically Restart within 15 minutes.
Step
Cause
Remedy
1
Connection failure of the fuser
unit harnesses
Check the connection of fuser unit harnesses,
and reconnect them if necessary.
2
Connection failure of the eject
sensor PCB harness
Check the connection of the eject sensor PCB
harness, and reconnect it if necessary.
3
Fuser unit failure
Replace the fuser unit.
4
Eject sensor PCB failure
Refer to
"1.3.10 Check sensor operation
(function code: 32)" in Chapter 5
to check the
sensor operation. If the sensor operation is
faulty, replace the eject sensor PCB ASSY.
5
Low-voltage power supply PCB
failure
Replace the low-voltage power supply PCB
ASSY.
6
Main PCB failure
Replace the main PCB ASSY.
CAUTION:
• Turn OFF the power switch. After the fuser unit has cooled sufficiently, turn ON the
power switch again and leave the machine for ten minutes. This problem may then be
cleared.
---
Step
Cause
Remedy
1
Main PCB failure
Replace the main PCB ASSY.
Содержание MFC-8510DN
Страница 27: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Страница 43: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Страница 53: ...2 8 Confidential 2 2 2 Scanning Legal model Fig 2 5 A4 model Fig 2 6 Document feed path Document feed path ...
Страница 143: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Страница 154: ...3 8 Confidential Develop joint gear 37 Fig 3 4 Document scanner unit A4 model Fig 3 5 Legal model Fig 3 6 ...
Страница 155: ...3 9 Confidential Hinge ASSY L Fig 3 7 Hinge R Legal model only Fig 3 8 ...
Страница 165: ...3 19 Confidential 11 Main frame R Harness colors may be changed for any reason NCU earth harness BR Guides ...
Страница 201: ...3 55 Confidential 13 Remove the LCD and touch panel ASSY from the panel cover Fig 3 70 Touch panel ASSY Panel cover LCD ...
Страница 277: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 293: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Страница 300: ...5 5 Confidential Fig 5 1 ...
Страница 325: ...5 30 Confidential Fig 5 14 ...
Страница 327: ...5 32 Confidential Fig 5 15 ...
Страница 346: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Страница 348: ...6 1 Confidential 1 WIRING DIAGRAM Wiring diagram ...
Страница 349: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Страница 368: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Страница 372: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...