S-7200B
3. FUNCTION SETTINGS (OPERATION PANEL)
10
Function No. 56
−
60
No.
Initial value
Setting range
Setting details
56 0 0
–
1
Function for preventing needle bar operation when treadle is accidentally
depressed forward when it is returned to neutral after being depressed
backward
0: Used
1: Not used
57
(NOTE 17)
0
0
–
1
Operation when treadle is depressed forward to 1st step when presser foot is
raised
0: Presser foot is lowered
1: Presser foot is not lowered
58 2 0
–
2
Synchronization function when quick reverse mechanism has been operated
using the actuator switch
0: Disabled
1: Only quick reverse mechanism synchronization enabled
2: Synchronization of main shaft at automatic deceleration speed set by No. 50
59 0
(degrees)
0
–
355
(degrees)
[Do not change this setting]
60
150
(degrees)
0
–
355
(degrees)
[Do not change this setting]
(NOTE 17) Setting is only enabled when DIP switch 2 is set to ON.
<Needle breakage prevention function specifications>
* Use Function No. 50 to set the automatic deceleration speed when the quick reverse mechanism has been operated using
the actuator switch.(Setting possible in units of 100 rpm)
* Use Function No. 58 to set the synchronization function when the quick reverse mechanism has been operated using the
actuator switch.
(Example) Default settings: At low speed: 0°; At high speed: 150°
Needle up stop point is home point
Direction of main shaft rotation
Operating angle range
Operating angle
(At low speed: No. 59)
(At high speed: No. 60)
0654B