4. FUNCTION SETTINGS
16
KE-430F, BE-438F
No.
Setting range
Initial value
Setting units
Setting details
407
1
−
999,
C01
−
C30
1 -
Program No. assigned to the F1 key
* Enabled when No. 406 is set to “3”.
408
1
−
999,
C01
−
C30
2 -
Program No. assigned to the F2 key
* Enabled when No. 406 is set to “3”.
409
1
−
999,
C01
−
C30
3 -
Program No. assigned to the F3 key
* Enabled when No. 406 is set to “3”.
410
1
−
999,
C01
−
C30
4 -
Program No. assigned to the F4 key
* Enabled when No. 406 is set to “3”.
451 ON/OFF
OFF
-
Split mode selection
ON: Independent split mode
OFF: Continuous split mode
430F: 40.0
460
0.0
−
40.0
(mm)
438F: 6.4
0.1
X direction sewing area limitation
430F: 40.0
461
0.0
−
30.0
(mm)
438F: 6.4
0.1
Y direction sewing area limitation
462
0
−
8
0 1
Enlargement/reduction reference point
0: Center of sewing frame
1: Sewing start point
2: Center of pattern
3: Front of pattern center
4: Back of pattern center
5: Back-left corner of sewing area
6: Front-left corner of sewing area
7: Back-right corner of sewing area
8: Front-right corner of sewing area
463 ON/OFF
OFF
-
Enlargement/reduction of bar tacking
ON: Bar tacking stitch lengths (pitch less than approx. 1 mm)
are also enlarged or reduced.
OFF: Bar tacking stitch lengths (pitch less than approx. 1 mm)
are not enlarged or reduced.
465
1
−
3
1
1
Setting parallel movement amount for sewing pattern
1: The parallel movement amount for the currently-selected
program can be set in parallel movement mode.
The movement amount is initialized when the power is
turned off and when the program number, pattern number,
X-scale or Y-scale is changed.
2: The parallel movement amount for the currently-selected
program can be set in parallel movement mode.
The movement amount is retained when the power is
turned off, but is initialized when the program number,
pattern number, X-scale or Y-scale is changed.
3: The movement amount can be set for each program using
parameters.
The movement amount is retained when the power is
turned off and when the program number, X-scale or
Y-scale is changed, but is initialized when the pattern
number is changed.
469 ON/OFF
OFF
-
Tension value setting
ON: A common tension value is set for all programs.
* Uniform correction operations are not possible.
OFF: Set separately for each program.
470 ON/OFF
OFF
-
Work clamp/button clamp height setting for each program
ON: Work clamp/button clamp height is set separately for each
program.
OFF: A common work clamp/button clamp height is set for all
programs.
* The work clamp/button clamp height is set by Nos. 471
and 472.
430F: 10
−
17
(mm)
14
471
438F: 6
−
13
(mm)
10
1
Work clamp/button clamp raise position setting
* Enabled when No. 470 is set to “OFF”.
Содержание KE-430F Series
Страница 45: ...5 EDITING PATTERN DATA 35 KE 430F BE 438F 5 2 Work flowchart 2922B ...
Страница 149: ...15 ELECTRIC MECHANISM 139 KE 430F BE 438F Power PCB Panel PCB 2932B 2687B ...
Страница 155: ...15 ELECTRIC MECHANISM 145 KE 430F BE 438F 2953B ...
Страница 156: ...15 ELECTRIC MECHANISM 146 KE 430F BE 438F 2954B ...
Страница 157: ...15 ELECTRIC MECHANISM 147 KE 430F BE 438F 2955B ...
Страница 181: ...18 7 SEGMENT DISPLAY LIST 171 KE 430F BE 438F 18 7 SEGMENT DISPLAY LIST 4268M ...
Страница 182: ...MEMO 172 KE 430F BE 438F ...
Страница 183: ...MEMO 173 KE 430F BE 438F ...
Страница 184: ...SERVICE MANUAL 2011 Brother Industries Ltd All Rights Reserved KE 430F BE 438F I0070967B 2011 04 B 2 ...