5-66
Confidential
<Details>
Item
Description
Setting
USBNo.
When the OS of the computer is
Windows Vista
®
, it might not be able
to obtain the serial No. of a USB
device depending on the computer
and USB device. To avoid this
problem, the return value of the
serial No. is switched to “0.”
USBNo. =ON
Returns the serial No. of the
device.
USBNo. =OFF
Returns “0.”
PS.DitherType
This function is to switch the dither
pattern when printed letters and/or
slanted lines are not smooth, and
thin lines are rough or uneven.
PS.DitherType=0
Improves roughness of letters
and slanted lines.
PS.DitherType=1
Alleviates banding.
DP.ImpGray
This function is to switch ON/OFF of
the print control for the gray color
when other colors are slightly
blended in the gray color or the gray
color is uneven upon printing.
DP.ImpGray=ON
Improves the symptom that other
colors are slightly blended in the
gray color.
DP.ImpGray=OFF
Improves the unevenness of the
gray color.
Regi Freq
This function is to switch the
threshold value which is used as the
timing to execute Auto Registration.
The threshold value can be
switched in three phases between
High, Mid, and Low.
Regi Freq=Mid
The frequency to execute Auto
Registration is middle.
Regi Freq=High
The frequency to execute Auto
Registration is high.
Regi Freq=Low
The frequency to execute Auto
Registration is low.
DX.XAdjust
This function is to adjust the left-end
print start position on the second
side in the left and right direction if it
is displaced in duplex printing.
The adjustable range is -100 to 750
(unit: 300 dpi) (The minus direction
means the left direction.)
DX.Xadjust=**
To move the print start position to
the left, press the
button and
decrease the value. To move the
print start position to the right,
press the
button and increase
the value.
DpSlp.StrDt
This function is to switch whether or
not to permit the printer to go into
Deep Sleep when StoreData
(Secure) exists in the main body.
DpSlp.StrDt =ON
Even when StoreData(Secure)
exists, the Deep Sleep function
operates.
DpSlp.StrDt =OFF
When StoreData(Secure) exists,
the Deep Sleep function does not
operate.
Special Printing
Dots appeared when hagaki printing
is performed can be alleviated by
changing the transfer current
setting.
(Only for Japanese hagaki printing)
Default
HAGAKI1
HAGAKI2
HAGAKI3
Содержание HL-4140CN
Страница 19: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Страница 29: ...Confidential CHAPTER 2 ERROR INDICATION AND TROUBLESHOOTING ...
Страница 145: ...Confidential CHAPTER 3 DISASSEMBLY AND ASSEMBLY ...
Страница 155: ...3 7 Confidential PG1 5 MOLYKOTE PG 661 W 1 5 mm dia ball PG1 5 PG1 5 Front cover arm L Front cover arm R Front cover ...
Страница 169: ...3 21 Confidential 8 DISASSEMBLY FLOW Disassembly Re Assembly second ...
Страница 236: ...3 88 Confidential 3 Remove the Filter ASSY from the Eject duct Fig 3 111 Eject duct Filter ASSY ...
Страница 274: ...3 126 Confidential 3 Disconnect the Connector from the Waste toner sensor Fig 3 174 Waste toner sensor Connector ...
Страница 296: ...Confidential CHAPTER 4 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 311: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Страница 336: ...5 23 Confidential Inter color position alignment adjustment chart Fig 5 8 ...
Страница 343: ...5 30 Confidential Fig 5 11 ...
Страница 345: ...5 32 Confidential Fig 5 12 First side Second side ...
Страница 347: ...5 34 Confidential Color test pattern Fig 5 13 MCYK Y C K M YCMK_ _A ...
Страница 354: ...5 41 Confidential Maintenance information Fig 5 14 ...
Страница 382: ...Confidential CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM ...
Страница 384: ...6 1 Confidential 1 CIRCUIT DIAGRAMS High voltage Power Supply PCB Circuit Diagram 1 3 ...
Страница 385: ...6 2 Confidential High voltage Power Supply PCB Circuit Diagram 2 3 ...
Страница 386: ...6 3 Confidential High voltage Power Supply PCB Circuit Diagram 3 3 ...
Страница 387: ...6 4 Confidential Low voltage Power Supply PCB Circuit Diagram 100V ...
Страница 388: ...6 5 Confidential Low voltage Power Supply PCB Circuit Diagram 200V ...
Страница 389: ...6 6 Confidential 2 WIRING DIAGRAM Wiring Diagram ...
Страница 390: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Страница 424: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Страница 428: ...Confidential APPENDIX 3 INSTALLING THE MAINTENANCE DRIVER ...
Страница 432: ...App 3 4 Confidential 10 Alert warning message appears click Continue Anyway to proceed ...