Error Code ED
Touch panel initialization failed.
■
Error Code F0
Flash file system error.
Error Code FE
ROM data acquisition error.
Touchscreen Init. Failed
LCD
Step
Cause
Solution
1
Touch panel PCB defective
Replace the control panel ASSY.
2
Main PCB defective
Replace the main PCB ASSY.
Unable to print F0
LCD
Unable to print FE
LCD
Step
Cause
Solution
1
Program malfunctioning
Re-load the firmware.
2
Main PCB defective
Replace the main PCB ASSY.
Содержание DCP-J552DW
Страница 120: ...3 3 Confidential 2 PACKING 3_002 ...
Страница 127: ...3 10 Confidential 2 CIS flat cable 3_011 CIS flat cable Cable guide Cable guide Flat core ...
Страница 220: ...4 10 Confidential ADF Copy Chart C A B D ...
Страница 241: ...5 9 Confidential Print Pattern for Creating Head Calibration Data Fit this mark on the left rear of ...
Страница 244: ...5 12 Confidential Scanning Compensation Data List ...
Страница 246: ...5 14 Confidential Test Pattern ...
Страница 254: ...5 22 Confidential MFC J450DW J470DW J475DW MFC J650DW J870DW J875DW ...
Страница 270: ...5 38 Confidential pfadj1 Pattern ...
Страница 271: ...5 39 Confidential pfadj2 Pattern ...
Страница 272: ...5 40 Confidential pfadj3 Pattern ...
Страница 278: ...5 46 Confidential Vertical Lines Check Pattern ...
Страница 279: ...5 47 Confidential Ruled Lines Check Pattern ...
Страница 283: ...5 51 Confidential Margin Check Pattern ...
Страница 284: ...5 52 Confidential Margin Check Pattern ...
Страница 314: ...6 3 Confidential Power supply PCB 100 V series ...
Страница 315: ...6 4 Confidential Power supply PCB 200 V series ...
Страница 329: ...App 3 8 Confidential When the following screen appears click Close to close the screen ...