![Brother DCP-J552DW Скачать руководство пользователя страница 67](http://html.mh-extra.com/html/brother/dcp-j552dw/dcp-j552dw_service-manual_53427067.webp)
2-34
Confidential
■
Error Code 44
The head driver IC detected an abnormal temperature during operation or stand-by.
■
Error Code 46
Purge count or flushing count overflown.
For details on how to reset the purge count and flushing count, refer to
.
■
Error Code 48
Head flat cable detected to be not correctly inserted.
Unable to print 44
LCD
Step
Cause
Solution
1
Insufficient ink inside the head
Perform initial purge.
2
Head property information not
input
Input the head property information.
(Refer to
)
3
Carriage PCB defective
Replace the carriage PCB ASSY.
4
Head defective
Replace the head/carriage unit.
5
Main PCB defective
Replace the main PCB ASSY.
Ink Absorber Full
LCD
Step
Cause
Solution
1
The ink absorber box or flushing
box is full
Replace the ink absorber box or flushing box and
reset the purge count and flushing count.
2
Main PCB defective
Replace the main PCB ASSY.
Unable to print 48
LCD
Step
Cause
Solution
1
Head flat cable connection failure
Reconnect the head flat cable.
2
Carriage flat cable connection
failure
Reconnect the carriage flat cable.
3
Carriage PCB defective
Replace the carriage PCB ASSY.
4
Head defective
Replace the head/carriage unit.
5
Main PCB defective
Replace the main PCB ASSY.
Содержание DCP-J552DW
Страница 120: ...3 3 Confidential 2 PACKING 3_002 ...
Страница 127: ...3 10 Confidential 2 CIS flat cable 3_011 CIS flat cable Cable guide Cable guide Flat core ...
Страница 220: ...4 10 Confidential ADF Copy Chart C A B D ...
Страница 241: ...5 9 Confidential Print Pattern for Creating Head Calibration Data Fit this mark on the left rear of ...
Страница 244: ...5 12 Confidential Scanning Compensation Data List ...
Страница 246: ...5 14 Confidential Test Pattern ...
Страница 254: ...5 22 Confidential MFC J450DW J470DW J475DW MFC J650DW J870DW J875DW ...
Страница 270: ...5 38 Confidential pfadj1 Pattern ...
Страница 271: ...5 39 Confidential pfadj2 Pattern ...
Страница 272: ...5 40 Confidential pfadj3 Pattern ...
Страница 278: ...5 46 Confidential Vertical Lines Check Pattern ...
Страница 279: ...5 47 Confidential Ruled Lines Check Pattern ...
Страница 283: ...5 51 Confidential Margin Check Pattern ...
Страница 284: ...5 52 Confidential Margin Check Pattern ...
Страница 314: ...6 3 Confidential Power supply PCB 100 V series ...
Страница 315: ...6 4 Confidential Power supply PCB 200 V series ...
Страница 329: ...App 3 8 Confidential When the following screen appears click Close to close the screen ...