Fixed needle guard position adjustment
1. Turn the pulley counterclockwise rotation, and
then set the needle at the position of the figure.
2. Loosen the screw (screw, bind M2x4) for the
fixed needle guard.
3. Move the fixed needle guard, and then adjust the
gap of the needle to 0 to 0.05 mm.
4. Fasten the screw (screw, bind M2x4) for the
fixed needle guard.
Pulley
Lower looper
Movable
needle guard
Needle plate
Needle
UL lever
Lower
looper
Contact to
the end face
Needle (left)
Needle plate
Screw, bind M2x4
Fixed needle guard
0 to 0.05 mm
Needle
(left)
Lower
looper
Movable
needle guard
Fixed needle
guard
Fixed needle
guard
Needle plate
Needle (left)
Screw, bind M2x4
Fixed needle guard
Needle plate