-26-
3.
NEEDLE DOWN POSITION ADJUSTMENT
STANDARD
When test mode "4" is selected, the needle should be exactly at the middle of the needle plate hole in the needle
down position.
ADJUSTMENT
1.
Select test mode "4".
2.
Turn the balance wheel to move the needle to the needle down position.
3.
Loosen the screw securing the zigzag adjusting nut.
4.
Turn the balance wheel to move the needle to the left and right, and then turn the zigzag adjusting nut by
using the box wrench to set the needle in the center of the needle hole.
5.
Tighten the screw securing the zigzag adjusting nut.
6.
Turn the balance wheel and check the needle down position.