background image

© 2007-2008 Broseley Fires Ltd 

 

1.

 

VERONA

 

11

 

&

 

16

 

TECHNICAL

 

DATA

 

 

 

2.

 

TECHNICAL

 

DESCRIPTION

 

 

The

 

VERONA

 

11

 

&

 

16

  

wood

 

burning

 

stoves

 

are

 

suitable

 

for

 

heating

 

living

 

spaces

 

within

 

a

 

home

 

or

 

supporting

 

a

 

central

 

heating

 

system.

 

If

 

fitted

 

with

 

the

 

hot

 

plate

 

the

 

stove

 

will

 

also

 

be

 

suitable

 

for

 

cooking

 

a

 

wide

 

variety

 

of

 

food

 

stuffs.

   

They

 

are

 

ideal

 

for

 

holiday

 

apartments

 

and

 

weekend

 

houses

 

or

 

as

 

a

 

heating

 

system

 

during

 

the

 

whole

 

year.

  

 

The

 

VERONA

 

11

   

&

 

16

   

stove

 

are

 

made

 

of

 

cast

 

iron

 

and

 

plates

 

of

 

steel

 

metal

 

sheet.

 

The

 

fire

 

chamber

 

is

 

internally

 

lined

 

with

 

cast

 

iron

 

firebricks.

 

There

 

is

 

a

 

turning

 

and

 

extractable

 

grate.

 

The

 

stove

 

is

 

equipped

 

with

 

a

 

panoramic

 

door

 

with

 

ceramic

 

glass

 

(resistant

 

up

 

to

 

700

 

ºC)

 

this

 

allows

 

a

 

wonderful

 

view

 

of

 

the

 

flame

 

picture,

 

whilst

 

also

 

preventing

 

outputs

 

of

 

sparks

 

and

 

smoke.

 

There

 

is

 

also

 

the

 

option

 

of

 

a

 

Verona

 

11

  

&

 

16

  

stove

 

with

 

a

 

hot

 

plate,

 

allowing

 

you

 

to

 

cook

 

on

 

the

 

stove.

 

 

The

 

appliance

 

is

 

equipped

 

with

 

primary

 

and

 

secondary

 

air

 

controls,

 

by

 

which

 

it

 

is

 

possible

 

to

 

control

 

the

 

burn

 

rate

 

and

 

hence

 

the

 

output

 

of

 

the

 

appliance.

  

 
 

 
 
 
 
 
 
 
 
 
 

Stove

 

Model:

 

Verona

 

11

 

Verona

 

16

 

Total

 

power

 

output

 

11

 

Kw

 

(37,543

 

btu)

16

 

Kw

 

(54,600

 

btu)

Wood

 

consumption

 

per

 

hour

  

(20%

 

humidity

 

)

 

2.6

 

kg/h

 

(MAX)

3.6

 

kg/h

 

(MAX)

 

Flue

 

Pipe

 

Diameter

 

150mm

 

/

 

6inches

 

150mm

 

/

 

6inches

 

Flue

 

draw

 

(Hot)

 

1.0

1.2 H

2

O

 

(water

 

gauge)

 

1.0

1.2

 

H

2

O

 

(water

 

gauge)

(Tested

 

after

 

one

 

hour)

 

10

12

 

PASCAL

10

12

  

PASCAL

FREE

 

AIR

 

VENT

 

SIZE

 

550

 

mm

2

minimum

 

+

 

550

 

mm

2

 

minimum

 

+

 

550

 

mm

2

per

 

Kw

 

over

 

5

550

 

mm

2

 

per

 

Kw

 

over

 

5

TOTAL

 

WEIGHT

 

OF

 

THE

 

APPLIANCE

 

150kg

 

(without

 

hot

 

plate)

190kg

 

(without

 

hot

 

plate)

165kg

 

(with

 

hot

 

plate)

218kg

 

(with

 

hot

 

plate)

WIDTH

  

670mm

 

(without

 

hot

 

plate)

790mm

 

(without

 

hot

 

plate)

670

 

(with

 

hot

 

plate)

800

 

(with

 

hot

 

plate)

DEPTH

  

450mm

 

(without

 

hot

 

plate)

520mm

 

(without

 

hot

 

plate)

590mm

 

(with

 

hot

 

plate)

660mm

 

(with

 

hot

 

plate)

HEIGHT

 

from

 

floor

 

to

 

top

 

of

 

lid

 

(with

 

lid

 

shut)

 

710mm

 

(without

 

hot

 

plate)

780mm

 

(without

 

hot

 

plate)

760mm

 

(with

 

hot

 

plate)

830mm

 

(with

 

hot

 

plate)

TEMPERATURE

 

OF

 

EXHAUST

 

GASSES

   

WOOD=

 

332

  

0

C

WOOD=

 

367

  

0

C

 

Содержание VERONA 11

Страница 1: ...OVER THE HOTPLATE AND NON HOTPLATE OPTIONS PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OPERATING OR SERVICING THIS APPLIANCE A Declaration of Completion Certificate must be obtained fo...

Страница 2: ...cles takes place within the firebox to maximize the heat output of the appliance and to minimize the discharge of particulate emissions to the atmosphere It is important therefore for appliances to be...

Страница 3: ...YOUR STOVE IMPORTANT NOTES 7 0 LIGHTING AND MAINTAINING A LOG FIRE 8 0 ASH REMOVAL 9 0 WOOD ASH DISPOSAL 10 0 OPERATING IN TRANSITION PERIODS SUMMER 11 0 MAINTENANCE CLEANING THE APPLIANCE 12A RECOMM...

Страница 4: ...ok on the stove The appliance is equipped with primary and secondary air controls by which it is possible to control the burn rate and hence the output of the appliance Stove Model Verona 11 Verona 16...

Страница 5: ...ce must be correctly sized to suit the space and necessary clearances must be strictly adhered to The appliance and flue system must be correctly installed to the current regulations in force at the t...

Страница 6: ...of the flames Having clean glass also improves the heat radiation to be uninterrupted This control will be used to adjust the combustion rate inside the fire chamber 4C THE THERMOSTAT CONTROL lever Th...

Страница 7: ...e green and have a fair amount of water content It will need to be stored in a well ventilated shelter to season it Wood used in this appliance must have a moisture content of less than 20 Damp or wet...

Страница 8: ...new heating season 7 0 LIGHTING AND MAINTAINING A LOG FIRE All chimneys and flues act differently After a while you will find out how your unit works best for starting Use scrunched up paper and dry k...

Страница 9: ...ts of hot embers can stay dormant for long periods when buried in ashes These will then flare up again when exposed to oxygen some knowledge of proper ash removal is required for safety Here are the i...

Страница 10: ...THE APPLIANCE Take great care choosing the products you use to clean your appliance A major amount of cleaning can be carried out using hot soapy water and a soft cloth Using the wrong products will...

Страница 11: ...s that are specially designed to remove hydrocarbon soot and fly ash mineral deposits from the glass Follow the manufacturers instructions Typically just spray a small amount of cleaner on the glass a...

Страница 12: ...of cleaning and sweeping of the flue Flue pipe should be fitted inside the flue pipe collar spigot to prevent creosote and condensates from running down onto the top of the appliance All flue pipe has...

Страница 13: ...O NON FLAMMABLE MATERIALS The minimum distance from any NON FLAMMABLE object or one that is NOT sensitive to heat stone brick slate etc and from materials with non flammable structure must be 100 mm s...

Страница 14: ...2007 2008 Broseley Fires Ltd 16 0 Fitting the Spigot and Blanking Plate...

Страница 15: ...ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE 3RD YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE 4TH YEAR SERVICE completion date SERVICE ENGINEER R...

Страница 16: ...ioned units Replaced parts or components will become the property of Broseley Fires Should you wish to claim under the warranty please contact the supplier dealer from whom you purchased the appliance...

Отзывы: