background image

© 2007-2008 Broseley Fires Ltd 

13.0

 

INSTALLATION

 

OF

 

THE

 

APPLIANCE

 

 

13.A

 

 

FLUE

 

REQUIREMENTS

 

 

The

 

chimney

 

is

 

possibly

 

the

 

most

 

important

 

part

 

to

 

your

 

installation;

 

great

 

care

 

should

 

be

 

given

 

to

 

its

 

design.

 

An

 

older

 

chimney,

 

in

 

need

 

of

 

repair,

 

is

 

a

 

fire

 

hazard

 

in

 

any

 

installation.

  

The

 

chimney

 

must

 

be

 

thoroughly

 

swept,

 

checked

 

for

 

soundness

 

and

 

suitability,

 

before

 

any

 

connection

 

is

 

made

 

to

 

the

 

appliance.

 

This

 

must

 

be

 

carried

 

out

 

by

 

a

 

qualified

 

person.

 

A

 

“Declaration

 

of

 

Completion”

 

certificate

 

must

 

be

 

obtained

 

by

 

the

 

end

 

user

 

for

 

the

 

installation,

 

failure

 

to

 

obtain

 

this

 

document

 

may

 

void

 

the

 

products

 

warranty.

 

 

 

This

 

appliance

 

must

 

be

 

installed

 

into

 

a

 

‘Class

 

1

 

Chimney’.

 

If

 

there

 

is

 

no

 

existing

 

chimney,

 

then

 

an

 

approved

 

solid

 

fuel,

 

factory

 

built,

 

prefabricated

 

block

 

type

 

or

 

a

 

twin

 

walled,

 

stainless

 

steel

 

flue

 

can

 

be

 

used.

 

Get

 

advice

 

from

 

a

 

qualified

 

chimney

 

engineer.

 

 

The

 

flue

 

diameter

 

of

 

this

 

appliance

 

must

 

be

 

a

 

minimum

 

of

 

150mm.

 

 

In

 

order

 

for

 

the

 

appliance

 

to

 

perform

 

satisfactorily,

 

the

 

chimney

 

height

 

must

 

not

 

be

 

less

 

than

 

4

 

meters

 

measured

 

vertically

 

from

 

the

 

stove

 

outlet

 

to

 

the

 

top

 

of

 

the

 

chimney.

 

 

Adequate

 

access

 

for

 

sweeping

 

the

 

flue,

 

such

 

as

 

a

 

soot

 

door,

 

must

 

be

 

provided.

 

This

 

will

 

dramatically

 

improve

 

the

 

ease

 

of

 

cleaning

 

and

 

sweeping

 

of

 

the

 

flue.

 

 

Flue

 

pipe

 

should

 

be

 

fitted

 

inside

 

the

 

flue

 

pipe

 

collar

 

(spigot)

 

to

 

prevent

 

creosote

 

and

 

condensates

 

from

 

running

 

down

 

onto

 

the

 

top

 

of

 

the

 

appliance.

 

 

All

 

flue

 

pipe

 

has

 

to

 

be

 

suitable

 

for

 

solid

 

fuel

 

and

 

fitted

 

in

 

accordance

 

with

 

building

 

regulations,

 

whilst

 

complying

 

with

 

current

 

legislation

 

and

 

manufacturers’

 

instructions.

 

 

If

 

excessive

 

draw

 

is

 

present,

 

then

 

a

 

suitable

 

draught

 

stabilizer

 

should

 

be

 

fitted.

  

This

 

must

 

be

 

fitted

 

in

 

the

 

same

 

room

 

as

 

the

 

appliance

 

is

 

located.

 

 

If

 

the

 

chimney

 

suffers

 

from

 

down

 

draught,

 

then

 

a

 

special

 

‘anti

downdraught’

 

cowl

 

will

 

need

 

to

 

be

 

fitted.

 

In

 

exposed

 

windy

 

locations,

 

a

 

‘stabilizing’

 

cowl

 

may

 

need

 

to

 

be

 

fitted.

 

The

 

minimum

 

cowl

 

requirement

 

that

 

we

 

recommend,

 

is

 

a

 

rain

 

cowl

 

with

 

a

 

bird

 

guard.

  

 

No

 

flue

 

sharing

 

with

 

other

 

appliances

 

is

 

allowed.

 

 

If

 

a

 

rear

 

flue

 

is

 

able

 

to

 

be

 

fitted,

 

the

 

horizontal

 

length

 

must

 

be

 

no

 

longer

 

than

 

150mm.

 

 

 

13B

 

 

LINING

 

THE

 

FLUE

 

 

An

 

insulated

 

chimney

 

is

 

the

 

most

 

efficient

 

and

 

safe

 

way

 

to

 

burn

 

wood.

  

An

 

insulated

 

chimney

 

helps

 

prevent

 

the

 

formation

 

of

 

tar

 

deposits.

  

A

 

standard

 

chimney

 

will

 

gradually

 

get

 

saturated

 

in

 

tar,

 

this

 

is

 

a

 

fire

 

hazard.

  

Tar

 

stains

 

may

 

appear

 

on

 

the

 

surface

 

of

 

the

 

chimney

 

breast

 

inside

 

the

 

property.

  

 

14.0

 

 

SITING

 

THE

 

APPLIANCE

 

 

This

 

appliance

 

must

 

not

 

be

 

fitted

 

into

 

a

 

location

 

where

 

it

 

will

 

be

 

impossible

 

to

 

service.

  

The

 

location

 

must

 

comply

 

with

 

the

 

requirements

 

laid

 

down

 

in

 

the

 

building

 

regulations.

  

 

 
 
 
 
 
 
 
 
 

Содержание VERONA 11

Страница 1: ...OVER THE HOTPLATE AND NON HOTPLATE OPTIONS PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OPERATING OR SERVICING THIS APPLIANCE A Declaration of Completion Certificate must be obtained fo...

Страница 2: ...cles takes place within the firebox to maximize the heat output of the appliance and to minimize the discharge of particulate emissions to the atmosphere It is important therefore for appliances to be...

Страница 3: ...YOUR STOVE IMPORTANT NOTES 7 0 LIGHTING AND MAINTAINING A LOG FIRE 8 0 ASH REMOVAL 9 0 WOOD ASH DISPOSAL 10 0 OPERATING IN TRANSITION PERIODS SUMMER 11 0 MAINTENANCE CLEANING THE APPLIANCE 12A RECOMM...

Страница 4: ...ok on the stove The appliance is equipped with primary and secondary air controls by which it is possible to control the burn rate and hence the output of the appliance Stove Model Verona 11 Verona 16...

Страница 5: ...ce must be correctly sized to suit the space and necessary clearances must be strictly adhered to The appliance and flue system must be correctly installed to the current regulations in force at the t...

Страница 6: ...of the flames Having clean glass also improves the heat radiation to be uninterrupted This control will be used to adjust the combustion rate inside the fire chamber 4C THE THERMOSTAT CONTROL lever Th...

Страница 7: ...e green and have a fair amount of water content It will need to be stored in a well ventilated shelter to season it Wood used in this appliance must have a moisture content of less than 20 Damp or wet...

Страница 8: ...new heating season 7 0 LIGHTING AND MAINTAINING A LOG FIRE All chimneys and flues act differently After a while you will find out how your unit works best for starting Use scrunched up paper and dry k...

Страница 9: ...ts of hot embers can stay dormant for long periods when buried in ashes These will then flare up again when exposed to oxygen some knowledge of proper ash removal is required for safety Here are the i...

Страница 10: ...THE APPLIANCE Take great care choosing the products you use to clean your appliance A major amount of cleaning can be carried out using hot soapy water and a soft cloth Using the wrong products will...

Страница 11: ...s that are specially designed to remove hydrocarbon soot and fly ash mineral deposits from the glass Follow the manufacturers instructions Typically just spray a small amount of cleaner on the glass a...

Страница 12: ...of cleaning and sweeping of the flue Flue pipe should be fitted inside the flue pipe collar spigot to prevent creosote and condensates from running down onto the top of the appliance All flue pipe has...

Страница 13: ...O NON FLAMMABLE MATERIALS The minimum distance from any NON FLAMMABLE object or one that is NOT sensitive to heat stone brick slate etc and from materials with non flammable structure must be 100 mm s...

Страница 14: ...2007 2008 Broseley Fires Ltd 16 0 Fitting the Spigot and Blanking Plate...

Страница 15: ...ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE 3RD YEAR SERVICE completion date SERVICE ENGINEER REG No COMPANY NAME COMPANY ADDRESS POSTCODE 4TH YEAR SERVICE completion date SERVICE ENGINEER R...

Страница 16: ...ioned units Replaced parts or components will become the property of Broseley Fires Should you wish to claim under the warranty please contact the supplier dealer from whom you purchased the appliance...

Отзывы: