Combustion Air Requirements
In order for the stove to perform efficiently and safely there should be an adequate air
supply into the room in which the stove is installed to provide combustion air. This is
particularly necessary in modern houses where drafts have been almost eliminated by
double glazing etc.
Under UK building regulations any appliance over 5kW MUST have a fixed
permanent air vent. The requirement calls for 550mm
2
of free ventilation per kW
above the 5kW threshold, which means that this appliance will require a fixed
permenant air vent that provides 25 x 550mm
2
of combustion air.
There must not be an extractor fan fitted in the same room as the stove as this can cause
the stove to emit fumes into the room.
(see building regulations approved document J for further information).