18
V. 3.1-300317
brookvent.co.uk
4.5 Changing from top spigot to side spigot
Step 1.
Isolate the unit from the mains and ensure all supply circuits are disconnected.
Step 2.
Unscrew any duct connectors from the top that are required to be ducted from the side.
Step 3.
Unscrew and remove the side plugs where they are required to be ducted from the side.
The side plugs can be discarded but the screws are still required.
Step 4.
Screw the duct connectors that were removed from the top to the side of the unit were
the side plugs used to be. Ensure that the screw holes line up to the inserts.
Step 5.
With the duct connectors now fitted to the side of the unit the top plugs need to be fitted
to the top of the unit. There will be 4 of these in each box.
Step 6.
On each side of the top plug there is a ring, the ring on each side is a different diameter
to the other. The larger diameter fits in the centre holes and the smaller diameter fits in the
corner holes on the top of the unit.
Step 6.
With the plug in the correct orientation; line up the screw holes with the screw inserts
and push the plug into the hole (it should be a snug fit).
Step 7.
Screw the top plug in place.
Step 8.
The unit can be connected from the side with 1 to all 4 connections.
Side Plugs
Duct connectors
Top Plugs