17
V. 3.1-300317
brookvent.co.uk
Step 2.
Unscrew the two large screws in the front of the control panel and pull out the PCB module (B).
Step 3.
Unplug all the
leads, the connectors are all marked to match up with their corresponding internal connections.
Step 4.
Pull the mains cable through the unit.
Step 5.
Remove the filters (A).
Step 6.
At the face of the unit marked INVERTED; unscrew and remove the blank control panel (F).
Step 6.
At the face of the unit marked INVERTED; unscrew and remove the wall mount bracket (E).
Step 7.
Pull the fan cables and sensor cables through the unit and connect the leads to their colour coded lead on the
PCB module (B).
Step 8.
Push the PCB module (B) into the case and secure using the M10 screws (D) and washers (C).
Step 9.
Place the filters (A) back into the unit from the face of the unit marked INVERTED.
Step 10.
On the face of the unit marked STANDARD; fit the wall mounting bracket (E), even if it is a floor mounted unit.
Take care to not over tighten the bracket.
Step 11.
On the face of the unit marked STANDARD; pull the mains cable through the unit and feed it through the blank
control panel (F).
Step 12.
Secure the blank control panel using the M10 screws (D) and washers (C).