background image

 

4/19 

2.0  Safety 

 
The  following  information  must  be  read  carefully  to  ensure  safe  installation  and 
operation of the unit. 

 

2.1  General Safety 

 

 

The device should not be used for applications other than those specified in this 

manual. 

 

After  removing  the  product  from  its  packaging,  verify  its  condition.  In  case  of 

doubt, contact a qualified technician. Do not leave packaging within the reach of 

small children or people with disabilities. 

 

Do not touch the appliance with wet or damp hands/feet. 

 

This appliance can be used by children aged 8 years old and above and persons 
with reduced physical, sensory or mental capabilities or lack of experience and 
knowledge if they have been given supervision or instruction concerning use of 
the appliance in a safe way and understand the hazards involved. Children should 
not  play  with  the  appliance.  Cleaning  and  user  maintenance  should  not  be 
performed by children without supervision. 

 

Do not use the product in the presence of flammable vapours, such as alcohol, 
insecticides, gasoline, etc. 

 

If  any  abnormalities  in  operation  are  detected,  disconnect  the  device  from  the 

mains  supply  and  contact  a  qualified  technician  immediately.  Use 

only  original 

spare parts for repairs. 

 

The  electrical  system  to  which  the  device  is  connected  must  comply  with 
regulations. 

 

Before connecting the product to the power supply or the power outlet, ensure 
that: 

 

the  data  plate  (voltage  and  frequency)  corresponds  to  those  of  the 
electrical mains 

 

the electrical power supply/socket is adequate for maximum device power. 
If not

, contact a qualified technician.

 

 

The device should not be used as an activator for water heaters, stoves, etc., nor 
should  it  discharge  into  hot  air/fume  vent  ducts  deriving  from  any  type  of 
combustion unit. It must expel air outside via its own duct. 

 

Operating temperature: -

20°C up to +50°C.

 

 

The device is designed to extract clean air only, i.e. without grease, soot, chemical 
or corrosive agents, or flammable or explosive mixtures. 

 

Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.). 

 

Do not immerse the device or its parts in water or other liquids. 

 

Turn off the main switch whenever a malfunction is detected or when cleaning. 

 

For  installation  an  omni  polar  switch  should  be  incorporated  in  the  fixed 

wiring,  in  accordance  with  the  wiring  regulations,  to  provide  a  full 

Содержание AF 90-CYC-ONE-100

Страница 1: ...o uk Installation maintenance user manual Applicable to the following aircycle ONE models PRODUCT CODE DESCRIPTION AF 90 CYC ONE 100 aircycle ONE 100 AF 90 CYC ONE 150 aircycle ONE 150 single room hea...

Страница 2: ...0 Safety 4 2 1 General Safety 4 2 2 Responsibility of the Installer 5 2 3 Responsibility of the Occupant 5 3 0 Specifications Dimensions 6 3 1 Product versions 6 3 2 Detailed Specification 6 3 3 ErP D...

Страница 3: ...kling problems associated with condensation dampness such as mould growth It is recommended that two units are installed in pair when one unit is pulling the other is pushing Pair of units can be inst...

Страница 4: ...ance please follow all instructions provided If this product has been misused not properly maintained or handled carelessly it may lead to this guarantee being declared void Brookvent does not accept...

Страница 5: ...n are detected disconnect the device from the mains supply and contact a quali ed technician immediately Use only original spare parts for repairs The electrical system to which the device is connecte...

Страница 6: ...e air intake to ensure good combustion and proper equipment operation Install the product so that the impeller is not accessible from the air outlet side as veri ed by contact with the Test Finger tes...

Страница 7: ...ramic core high thermal efficiency External grille in high quality impact and UV resistant ABS colour RAL 9010 Unique design winglet type impeller providing enhanced aerodynamic properties low noise a...

Страница 8: ...power input SPI W m3 h 0 071 0 054 n1 Control factor 1 1 n2 Control typology Manual control no DCV o1 Maximum internal leakage rate N A o2 Maximum external leakage rate 1 1 p1 Internal mixing rate N A...

Страница 9: ...the integral jumpers as per g 20A 20B The front cover LED indicates when the Free cooling mode is on An automatic Boost mode can be achieved through a dedicated switch or room sensors like humidity se...

Страница 10: ...e cooling mode 4 3 Disposal and recycling Information on disposal of units at the end of life This product complies with EU Directive 2002 96 EC The symbol of the crossed out dustbin indicates that th...

Страница 11: ...10 19 5 0 Installation and figures...

Страница 12: ...11 19...

Страница 13: ...12 19...

Страница 14: ...13 19...

Страница 15: ...14 19...

Страница 16: ...15 19...

Страница 17: ...16 19...

Страница 18: ...17 19...

Страница 19: ...18 19 Notes...

Страница 20: ...happy to assist you Brookvent Brook House Dunmurry Industrial Estate Dunmurry Belfast Northern Ireland BT17 9HU T 44 0 28 9061 6505 It is important to retain this manual and make a copy available to...

Отзывы: