Installation and Operation Manual
X-DPT-EtherCAT-VDM300-eng
Part Number: 541B217AAG
March
, 201
9
Brooks
®
EtherCAT
®
VDM
Table 3-15 SDP and CDP Command Objects (Continued)
Index
Sub
Index
Data Type
Acce
ss
Name
Description
Start Calculation
A write access to this subindex shall only
set one bit true in Bit [0...7]. If other
values are written the Abort Code
"0x06040043 Parameter is incompatible"
shall be returned.
Bit 0 = 1: Use default checksum
algorithm of the slave
Bit 1 = 1: CRC-32
Bit 2 = 1: MD5
Bit 3 = 1: SHA-1
Bit 4-6: Reserved, shall be 0
Bit 7 = 1: other algorithm
Bit 8...31: Reserved, shall be 0
0x03
ARRAY
[0..n] OF
BYTE
RO
Response
Byte 0: see Subindex 2
Byte 1: Unused - Shall be zero
Byte 2-n: Checksum return value. Size
varies depending on checksum type
used. The maximum length shall be 64
bytes.
0xFBF4
RO
Load Parameters
Command
Execution of this command will load all
parameters from non-volatile memory. If
a device automatically saves all non-
volatile parameters at the time they are
written, this command will not take any
action.
Index
Sub
Index
Data Type
Acce
ss
Name
Description
0x01
ARRAY
[0..3] OF
BYTE
RW
Command
Read:
Bit 1 = 1: slave saves the non-volatile
parameters automatically when they are
written
Write: No action since slave saves the
non-volatile parameters automatically
0x02
USINT
RO
Status
"Supported values:
0: last command completed, no error, no
response
1: Reserved
2: last command completed, error, no
response
0x03
ARRAY
[0..1] OF
BYTE
RO
Response
"Byte 0: see Subindex 2