Содержание Electronics EIB603CX

Страница 1: ...roduct is being used It contains vital information on the operation and installation of your Smoke Alarm The leaflet should be regarded as part of the product If you are just installing the unit the l...

Страница 2: ......

Страница 3: ...UIDE LOCATION POSITIONING INSTALLATION INTERCONNECTION HARD WIRED TESTING MAINTENANCE POWER SUPPLY MONITORING FIRE SAFETY ADVICE ALARM LIMITATIONS GETTING YOUR ALARM SERVICED FIVE YEAR GUARANTEE TROUB...

Страница 4: ...art Guide LOCATE CORRECT SITING POINT FIX BASEPLATE TO CEILING Quick Start Guide ALARM SHOULD BE CEILING MOUNTED AT LEAST 300MM FROM WALLS OBSTRUCTIONS IDEALLY CENTRALLY IN ROOM AREA PLACE ALARM TWIST...

Страница 5: ...Quick Start Guide TEST ALARM TEST ALARM AT LEAST WEEKLY PRESS THE TEST BUTTON 5...

Страница 6: ...e installed in kitchens and other areas where Smoke Alarms are unsuitable EIB603CX and EIB650iWX are interconnected with hard wiring to the RFAP to give the loudest alarm sound level throughout the ho...

Страница 7: ...t from a room is often cool and slow moving so it can take a long time to rise to the ceiling and travel to a detector which could be some distance away A Heat Alarm in the closed room will give early...

Страница 8: ...ms should be placed in the kitchen garage Recommended Protection Fire authorities recommend you put individual Smoke Alarms in or near all rooms where fire is most likely to break out apart from the l...

Страница 9: ...in each sleeping area every 7 5 metres of hallways and rooms within 3 metres of all bedroom doors all units interconnected For recommended protection in addition to the above Smoke Alarms in every roo...

Страница 10: ...spreads out so a central ceiling position is the recommended location The air is dead and does not move in corners therefore Smoke Heat Alarms must be mounted away from corners Keep at least 0 3m fro...

Страница 11: ...n garages etc Locate away from very dusty or dirty areas as dust build up in the chamber can impair performance It can also block the insect screen mesh and prevent smoke from entering the smoke detec...

Страница 12: ...g the Alarm Surfaces that are normally warmer or colder than the rest of the room e g attic hatches Temperature differences might stop smoke or heat from reaching the unit Next to or directly above he...

Страница 13: ...g to the marked locations of each Alarm Make the connections to the interface card see Section 4 5 Taking care to avoid any electrical wiring in the ceiling drill holes using a 5 0mm drill bit through...

Страница 14: ...arm from the ceiling it is now necessary to use a small screwdriver to release the catch push catch towards the ceiling and then twist off the alarm see figure 7b If necessary it is possible to furthe...

Страница 15: ...MOVE Figure 7b How to Remove TAMPERPROOF SCREW Figure 7c 6 to 8 mm 2 to 3 mm SELF TAPPING SCREW Figure 7d Line up the screw not supplied on the U shaped recessed area shown in figure 7c and screw firm...

Страница 16: ...holes may blow smoke away from the sensing chamber making it insensitive It is essential that all such ceiling openings be closed with silicone sealant or similar 1 Run 1 1 5mm2 three core cable from...

Страница 17: ...aintenance Power Supply Monitoring Your Alarm is a life saving device and should be checked periodically Regularly check that the green light on the Alarm illuminates to show the units are powered Rep...

Страница 18: ...e Alarm sounds there is no sign of smoke or noise to indicate that there is a fire it should be assumed that it is due to an actual fire and the dwelling should be evacuated immediately Refer to the R...

Страница 19: ...n the maintenance and cleaning described in this leaflet no other customer servicing of this product is required Repairs when needed must be performed by the manufacturer 5 5 Dust Insect Contamination...

Страница 20: ...orn loudly when the test button is pressed Do not put the Alarm into a fire The Alarm should be disposed in a safe and environmentally sound manner at your local recycle centre Contact your local auth...

Страница 21: ...test hush button To maintain sensitivity to smoke heat do not paint or cover the Alarm in any manner do not permit any accumulation of cobwebs dust or grease If Alarm has been damaged in any way or do...

Страница 22: ...ns for smouldering cigarettes and ashes Service central heating systems regularly Be sure all electrical appliances and tools have a recognised approval label This device cannot protect all persons at...

Страница 23: ...to floor Take short breaths if possible through a wet cloth or hold your breath More people die from smoke inhalation than from flames 3 Get out as fast as you can Do not stop for packing Have a prear...

Страница 24: ...ire is too far away for example if the fire is on another floor behind a closed door in a chimney in a wall cavity or if the prevailing air draughts carry the smoke or heat away Installing Smoke Heat...

Страница 25: ...e Brooks guarantees this Alarm for five years from date of purchase against any defects that are due to faulty materials or workmanship This guarantee only applies to normal conditions of use and serv...

Страница 26: ...necessary Press the Test Hush button on the Smoke Alarm causing the Alarm this can be identified as the Alarm with the red light flashing rapidly this will silence the Smoke Alarm for 10 minutes and a...

Страница 27: ...27 Conforms to AS1603 3 2018...

Страница 28: ...28...

Страница 29: ...29...

Страница 30: ...Brooks com au VIC 9 71 Victoria Crescent Abbotsford VIC 3067 Ph 03 9879 5294 SA P O Box 101 Woodville SA 5011 729A Port Road Woodville SA 5011 Ph 08 8347 0000 QLD P O Box 511 Archerfield QLD 4108 2 4...