2

Do not use outdoors or near a fireplace or stove.

•  Do not drop or expose to electrical shocks.
•  The thermometer must only be use in an ambient 

temperature between 10°C and 40°C (50°F and 104°F) 

•  Do not expose this thermometer to extreme temperature

conditions of >50°C or <-20°C (>122°F or <-4°F)

• 

•  Do not attempt to sterilize the thermometer. 
•  The lens of the infrared sensor is the most fragile part. 

D

fingers.

o not touch the glass of the infrared sensor with your 

•  If necessary, clean the glass surface of the infrared sensor 

with a cotton swab dipped in 70% isopropyl alcohol. 

•  Do not use this thermometer if it is not functioning 

properly, or if it has been exposed to extreme 

conditions, damaged, immersed in water, or exposed to 

electrical shocks.

•  The only service you can perform on the device is to 

change the batteries. When doing so follow the 

Содержание VeraTemp

Страница 1: ...VeraTemp PersonalUse Non Contact Thermometer By Brooklands Inc READ INSTRUCTIONS BEFORE USE...

Страница 2: ...d for probe covers INTENDED USE The VeraTemp Non Contact Thermometer is an infrared thermometer for body surface and forehead tempurature measurements in Infants Children and Adults that does not requ...

Страница 3: ...he thermometer The lens of the infrared sensor is the most fragile part D fingers o not touch the glass of the infrared sensor with your If necessary clean the glass surface of the infrared sensor wit...

Страница 4: ...ing the VeraTemp Personal Non Contact Thermometer which has been developed using the most advanced technology This technology allows a forehead temperature to be taken from a distance of about 5 8 cm...

Страница 5: ...he approximate time that the result remains on the display after a reading is taken BodyTemperature andWhere It s Measured Body temperature is a measure of the body s ability to generate and dissipate...

Страница 6: ...old keep body temperature within a narrow safe range Body temperature can be measured in many locations of the body Most commonly temperature measurements are taken in the mouth ear armpit or rectum F...

Страница 7: ...6 and E1112 86 is 0 2 F 0 1 C This infrared thermometer meets Brooklands Incorporated requirements established in ASTM Standard E1965 98 Full responsibility for the conformance of this product tempera...

Страница 8: ...38 0 C Oral 95 9 F 99 5 F 35 5 C 37 5 C Axillary Armpit 94 5 F 99 1 F 34 7 C 37 3 C Forehead 95 0 F 100 4 F 35 0 C 38 0 C Normal BodyTemperatures and Age A ge Fah renheit C elsius 0 to 2 years 97 5 F...

Страница 9: ...ture will instantly be displayed on the screen The screen will be green when the measured temperature is between 36 3 C and 37 3 C 97 3 F to 99 1 F The VeraTemp Personal Non Contact Thermometer measur...

Страница 10: ...ter the button is released After the display Features Specially designed to take the body temperature of a person regardless of the room temperature Screen color changes related to temperature Last 32...

Страница 11: ...C to 37 9 C 99 3 F and 100 2 F Red Greater than 38 C 100 4 F NOTE The thermometer is set to Body mode at the factory Low Battery Memory Celsius Temperature Mode Fahrenheit The color change of the dis...

Страница 12: ...urface temp Body and Room SCAN Press to view and record a temperature reading Display Infrared lens Covers C F Press to switch between Celsius and Fahrenheit MEM Press to retrieve the last 32 readings...

Страница 13: ...12 Battery cover Two AAA batteries Note orientation of battery polarity Product label Model number Serial number Back...

Страница 14: ...ent must not have undertaken vigorous physical activity prior to temperature measurement Also the room temperature should be moderate 10 C to 40 C 50 F to 104 F When evaluating results consider the po...

Страница 15: ...o Receive a Stable Reliable Result Push back any hair from the forehead Wipe away any perspiration on the forehead Avoid drafts Allow a 5 second interval between temperature measurements If there is a...

Страница 16: ...re taking a temperature ensure the forehead is free of perspiration and that hair has been moved aside 2 W ith the thermometer about 5 8 cm 2 3 inches ay from the forehead press the SCAN button The te...

Страница 17: ...e results you may not be waiting the 5 seconds between uses to allow the previous temperature to be completed To check previous temperatures the memory function MEM records the previous 32 scans with...

Страница 18: ...m u h e d o m y d o B measurement 32 C to 42 9 C 89 6 F to 109 F 3 Power DC 3 volt two AAA batteries 4 Size 49 mm x 161 mm x 41 mm 1 9 in x 6 4 in x 1 6 in 5 Weight 85 g 3 oz without batteries 6 Disp...

Страница 19: ...k start card Storage bag Two AAA batteries Although The VeraTemp Personal Non Contact Thermometer can measure temperature below 32 C and above 42 9 C 89 6 F to 109 F these temperature s are outside th...