6 | SETTINGS MENU
9.17.048
Page 20
The following controller modes can be selected:
selection
description
analog input
Setpoint via analog input
bus/rs232
Setpoint via bus or RS232 (BRIGHT)
rs232
Setpoint via RS232 only (BRIGHT)
fb ana slave
Setpoint is factor of measure of
master on the bus, factor is set by
analog input.
analog slave
Setpoint is factor of analog input
fb slave
Setpoint is factor of measure of
master on the bus
valve open
Setpoint neglected, valve fully open
valve close
Setpoint neglected, valve closed
controller idle
Setpoint neglected, valve stays in
actual position
setpoint 100%
Setpoint is 100 perc.
setpoint 0%
Setpoint is 0 perc.
Use or to select one of these control modes. Press
to cancel selection and exit the edit mode
without changes
When the required control mode is selected, press
to
confirm.
6.8 Master slave settings
When you select one of the three slave modes the ‘master
slave’ option will be added to the controller settings
screen.
CANCEL
SET