background image

7

  1.  STARTING UP

The ballast unit EB 800.1600 is a flicker-free electronic ballast units which are made for mains 

voltages from 90 V to 265 V. They adjust automatically to the mains (AC-line) voltage applied.

The unit is suitable for operation with hot-restrike (HR) lamps. This means that the lamp may be 

switched on again at any time while hot, making waiting time unnecessary. For safety reasons, 
the high ignition voltages required for this purpose call for a faultless earth conductor. For this 
reason the unit must only be connected to a power supply with an earthed mains plug. Correct 
functioning of the earth conductor is indicated by the control lamp (3).

Step 1
Fit a compatible bulb to the lamp (see Section 2: Fitting or changing a bulb) and a reflector, an 
adapter for a Softbox or Para (see Section 3: Mounting and removing reflectors and adapters). The 
lamp is equipped with an integral safety switch (17), and can only be operated when a reflector or 
an adapter is mounted. When it is used with an adapter, the focusing wheel (11) must be turned 
to the “Bare Bulb” position (bulb as far forwards as it will go) so that the safety switch is actuated 
and the bulb can be fired.

Step 2
Connect the lamp to the ballast unit, and the ballast unit to the earthed mains supply. Switch on 
the main switch (2) and check whether the earth control LED (3) illuminates. If this is not the case, 
for safety reasons disconnect the ballast unit immediately from the mains and check the earth 
conductor.

Step 3
Operate switch (9) on the lamp and press button (4) on the ballast unit. The bulb fires and starts 
operating. By operating the switch (9) on the lamp or on the ballast unit (4), the light can be 
switched off again.

The ballast unit has an automatic warming-up circuit, which heats the bulb quickly to its operating 

temperature. Except in an emergency avoid switching off the unit during the warming-up phase, 
because this shortens the life of the bulb. The optimum colour temperature is reached after about 
one minute. 
Should the bulb fail to trigger, the ballast unit will switch off the ignition sequence after 2 seconds, 
and button (4) on the ballast unit blinks (see Section 7). To make another attempt to start, press 
the button (4) on the ballast unit or (9) on the lamp. To protect the igniter circuit, this is blocked 
for 30 seconds after about ten attempts at ignition. Afterwards further ignition attempts are pos-
sible. Take care that the ventilation slots are not obstructed on either the ballast unit or the lamp.

Step 4

The output regulator (8) on the ballast unit can be used to set the desired light output  (setting 

range 50 % 

 100 %). When setting the output, it is important to remember that, depending on the 

bulb used, the colour temperature can change slightly with the output. When the bulb is switched 
on, the output is automatically set to the maximum so that the bulb heats up as quickly as pos-
sible.  The duration of this depends on the bulb temperature when it is switched on, and is likely 
to be between 5 and 60 seconds. At the end of this period, the unit adjusts automatically to the 
setting of regulator (8).

 

Содержание D 1600

Страница 1: ...Operating instructions Bedienungsanleitung Mode d emploi D 1600 EB 800 1600...

Страница 2: ......

Страница 3: ......

Страница 4: ...Starting up 7 2 Fitting or changing a bulb 8 3 Mounting and removing reflectors and adapters 8 4 Fitting and removing accessories 8 5 Focusing 9 6 Operating the lamp with a Para 9 7 Operating modes 9...

Страница 5: ...th a steel cable To protect against the effects of radiated heat the lamp must not be directed at flammable surfaces and or surfaces sensitive to heat or any objects from less than a minimum distance...

Страница 6: ...ins and check the earth conductor Step 3 Operate switch 9 on the lamp and press button 4 on the ballast unit The bulb fires and starts operating By operating the switch 9 on the lamp or on the ballast...

Страница 7: ...ar the security pin 16 latch Take care not to damage the bulb while dismounting an accessory Removing Loosen the retaining screw 10 on the lamp then pull it straight backwards and hold it Turn the ref...

Страница 8: ...It is recommended that the lamp s yoke 21 is removed completely To remove it undo the screws 18 and pull the two carrier plates with the yoke towards the handle The complete yoke can now be removed P...

Страница 9: ...s to indicate this Low voltage protection If the applied voltage is below 90 V the ballast unit either switches off automatically or cannot be switched on Button 4 blinks to indicate this Current limi...

Страница 10: ...n on More than 10 ignition attempts Allow to cool blinks off blinks blinks on on on Technical fault Service station blinks blinks blinks blinks blinks blinks on 10 FAULT DIAGNOSIS TABLE Ballast units...

Страница 11: ...mp has been identified 8 Rotary knob for adjusting output dimmer 13 TECHNICAL DATA BALLAST UNIT EB 800 1600 Supply power rating 1800 VA Mains voltage 90 265 V Mains frequency 50 60 Hz Current draw 20...

Страница 12: ...13...

Страница 13: ...e for yoke 20 Slots for reflector or Softbox adapter 21 Yoke 22 28 mm 1 1 stand spigot with 16 mm 0 6 bore 23 Retaining screw 24 PAR reflector 25 Diffusion lens 26 Scrim ring 27 Four leaf barn door fo...

Страница 14: ...15...

Страница 15: ...0713 Fresnel lens 713 0534 Bag for 5 filters or lenses 763 0322 1600 W bulb G E CSR1600 SE HR UVC 633 7410 1600 W bulb Sylvania BA1600 SE HR UVC 633 7411 Lamp cable 7 5 m 742 0599 Lamp cable 10 m 742...

Отзывы: