background image

10

www.bromicheating.com

• 

Insert Black Ignitor Cable directly into control box 
using 2.8mm spade connector, located on the side 
of the controller

• 

Insert White Ionisation Cable directly into control 
box using 4.75mm spade connector, located on the 
side of the controller

• 

Insert Earth Terminal over earth tab, attached to body 
of control housing and marked with Earth Symbol

• 

Re-connect Honeywell control to the gas valve by 
positioning the controllers inbuilt Molex plug over 
the gas valve’s connector and carefully slide into 
place. Fix in place using the retaining screw.

INSTALLATION INSTRUCTIONS 

CONTINUED...

6.  Insert pivot Bolt

• 

Position Arm so that the rear hole’s on the mounting 
arm and Control Housing are in alignment

• 

Insert Bolt and washer (as supplied) through Control 
Housing and Mount Arm, using the hole located on 
the bottom surface of the Control Housing, towards 
the rear. Spanner tighten in place

• 

Select desired heater angle and insert the M6 Bolt 
and washer (as supplied) through the bottom surface 
of Control Housing into the mounting arm, using the 
corresponding hole. (Heaters angle will be 0º, 10º or 
20º). Spanner tighten in place

7.  Connect the 3 wires from the heater by carefully following 

the instructions below

For Honeywell control

• 

Disconnect Honeywell control from Honeywell gas 
valve by unscrewing retaining screw and pulling away 
from gas valve

ImPortant

Electrical connections must be completed by trained and 
authorized electrical technicians only!

!

Содержание PLATINUM 300 BURNER

Страница 1: ...nstallation operating and maintenance instructions thoroughly before installing or servicing this equipment DANGER If you smell gas 1 Shut off gas to the appliance 2 Extinguish any open flame 3 If odo...

Страница 2: ...death severe injury or property damage Installation must be carried out by Authorized person s in accordance with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z22...

Страница 3: ...ALLATION 12 LEAKAGE TEST 12 HEAT DEFLECTOR INSTALLATION INSTRUCTIONS 13 CEILING MOUNT POLE INSTALLATION INSTRUCTIONS 13 OPERATING INSTRUCTIONS 14 TURNING THE APPLIANCE ON 14 TURNING THE APPLIANCE OFF...

Страница 4: ...p solution Never use an open flame to check for leaks Do not use the heater until all connections have been leak tested by an authorized person Inspect the hose assembly before each use of the applian...

Страница 5: ...Pty Ltd 1 Suttor St Silverwater NSW 2128 Sydney Australia CSA Approval No 2345658 2345658 2345658 2345658 Gas Consumption 26 000 BTU 26 000 BTU 43 000 BTU 43 000 BTU Gas Type Propane Gas LPG Only Nat...

Страница 6: ...s with natural ventilation without stagnant areas where gas leakage and products of combustion are rapidly dispersed by wind and natural convection Any enclosure in which the appliance is used shall c...

Страница 7: ...nt clearances refer below Note When Installing with No protective cover the following installation clearances shall apply Minimum height to combustible materials Model A B C 300 Series 3ft 3ft 8ft 500...

Страница 8: ...side the centre of the arm and have them exit through the shaped cut out on top surface of the arm Ensure that the arm faces downwards at a 55 angle Position the 4 mounting holes on the arms plate ove...

Страница 9: ...ose so that the arm can slide into place TIP Do not install the mounting pin at this point Step 5 Connect the CSA approved flexible connector to the Gas Valve Outlet Fitting Position heater and hose s...

Страница 10: ...ion Arm so that the rear hole s on the mounting arm and Control Housing are in alignment Insert Bolt and washer as supplied through Control Housing and Mount Arm using the hole located on the bottom s...

Страница 11: ...ting to mains gas supply in accordance with local gas installation code and gas supply installation section of manual Leak test with soapy water 9 Fix Front cover to control housing using the 8xM4 scr...

Страница 12: ...s where the hose may be subject to accidental damage POWER SUPPLY INSTALLATION WARNING This heater is equipped with a three prong grounding plug for your protection against shock hazard and should be...

Страница 13: ...ounting bracket using the M8x100mm and M19x100mm bolts and fix using nuts and washers as supplied 3 Assemble both lower paddles to the pole back to back and insert 3 M10x100mm bolts and fix using nuts...

Страница 14: ...e is any evidence of excessive wear or if the hose is damaged The replacement hose assembly must be CSA approved with 3 8 SAE flared ends To Check the Gas Hose remove control housing cover by removing...

Страница 15: ...ent restoration of the mains power supply Features Compliance with CSA standard for automatic gas burner flame monitoring and control systems Compliance with EN 298 European standard for automatic gas...

Страница 16: ...ted and the gas valve remains energised If the control does not detect any flame signal during the safety time at the end of safety time TS the unit proceeds to lockout and the gas valve and ignition...

Страница 17: ...he ground terminal of the control the metal frame of the burner and the ground on the mains supply must be well connected Operation When a call for heat is received from the thermostat supplying 24 vo...

Страница 18: ...4 V 10 15 Load of coil 24 V 230 V 2 x 5 5 VA Electrical connection Molex System connection coil or Option Connection box with integrated cable Installation position Solenoid at any position between ve...

Страница 19: ...isation HONEYWELL Red 230 V Blue Purple Purple Ionisation Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18AWG 90 C type UL approved wire or its...

Страница 20: ...TRICAL COMPONENTS GND V 2 White S 1 T H V 1 Red Orange Yellow Green TRANSFORMER WHITE RODGERS Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18A...

Страница 21: ...NENTS GND V 2 White S 1 T H V 1 Red Orange Yellow Green TRANSFORMER DUNGS Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18AWG 90 C type UL appr...

Страница 22: ...22 www bromicheating com REPLACEMENT PARTS 1 2 3 4 5 9 10 11 24 8 12 23 6 22 7 17 13 16 19 20 15 13 14 19 White Rodger Honeywell...

Страница 23: ...0732 7 Control Mount 2620734 2620734 8 Rear Housing 2620815 2620816 9 Rear Cover Assembly 2620819 2620820 10 Burner 2620822 2620822 11 Wiring Harness Ignitor Assembly Honeywell 2620736 2620736 12 Inne...

Страница 24: ...n this site 3 Tile ________ 5 Tile ________ What type of gas is used LPG Natural Gas Is Are the heater s exposed to salt air or any other corrosive or chemical atmosphere Yes No Does the heater s inst...

Страница 25: ...ulator until at least 6 W C for natural gas or 11 W C for propane precedes heater s control assembly 3 Clean orifice 4 Provide adequate ventilation of by products 5 Replace manifold 6 Increase gas pre...

Страница 26: ...26 www bromicheating com APPENDIX A...

Страница 27: ...27 www bromicheating com APPENDIX A CONTINUED...

Страница 28: ......

Страница 29: ...AVERTISSEMENT Pour une utilisation l ext rieur uniquement AVERTISSEMENT N entreposez pas et n utilisez pas d essence ou d autres vapeurs ou liquides inflammables prox mit de cet appareil ou de tout au...

Страница 30: ...es graves voire mortelles ou des d g ts mat riels L installation doit tre effectu e par des personnes agr es en conformit avec les normes locales ou en leur absence avec la norme am ricaine sur le gaz...

Страница 31: ...DE L ALIMENTATION LECTRIQUE 40 TEST DE FUITES 40 INSTRUCTION D INSTALLATION DU D FLECTEUR THERMIQUE 41 INSTRUCTIONS D INSTALLATION DE LA TIGE DE MONTAGE AU PLAFOND 41 INSTRUCTIONS D UTILISATION 42 MIS...

Страница 32: ...es ventuelles N utilisez pas le radiateur avant que toutes ses connexions n aient t v rifi es au niveau de fuites ventuelles par une personne autoris e Inspectez l ensemble de conduites avant l utilis...

Страница 33: ...6 000 BTU 43 000 BTU 43 000 BTU Type de gaz Gaz propane LPG uniquement Gaz naturel Gaz propane LPG uniquement Gaz naturel Pression max de conduite 14 de colonne d eau 14 de colonne d eau 14 de colonne...

Страница 34: ...mortes dispersion rapide des fuites de gaz et des produits de combustion par le vent et la convection naturelle Tout abri dans lequel l appareil est utilis doit tre conforme l un de ceux ci 1 Un abri...

Страница 35: ...llation SANS couverture de protection les cartements d installation suivants doivent s appliquer Hauteur minimale par rapport des mat riaux combustibles Mod le A B C S rie 300 3 90 cm 3 90 cm 8 2 4 m...

Страница 36: ...tallation doit tre effectu e par une personne de service qualifi e tape 2 Branchez le connecteur de gaz flexible approuv CSA tel que fourni sur le raccord d arriv e du radiateur en utilisant 2 cl s po...

Страница 37: ...sser en place CONSEIL N installez pas la goupille de montage ce stade tape 5 Branchez le connecteur flexible approuv CSA sur le raccord de sortie de la vanne de gaz Positionnez le radiateur de fa on c...

Страница 38: ...on ce que les trous arri re du bras de montage et du bo tier de commande soient en alignement Ins rez boulon et rondelle fournis au travers du bo tier de commande et du bras de montage en utilisant le...

Страница 39: ...ec les normes pour installations au gaz et la section d installation du gaz de ce manuel Effectuez un test de fuite avec de l eau savonneuse 9 Fixez le couvercle frontal au bo tier de commande en util...

Страница 40: ...TISSEMENT Ce radiateur est quip d une fiche secteur trois broches avec terre pour votre protection contre le risque d lectrocution qui doit tre ins r e directement dans une prise secteur trois broches...

Страница 41: ...tige au support de montage en utilisant les boulons M8 de 100 mm ou M19 de 100 mm et fixez avec des crous et rondelles fournis 3 Assemblez les deux palettes inf rieures la tige dos dos et ins rez 3 bo...

Страница 42: ...e en tant 8 vis et sortez le couvercle en le glissant Comme alternative vous d montez le radiateur en inversant les instructions d installation d crites dans la section d installation de ce manuel 2 V...

Страница 43: ...rique Caract ristiques Conformit avec la norme CSA sur les syst mes automatiques de surveillance et contr le de flamme de br leurs au gaz Conformit avec la norme europ enne EN298 sur les syst mes auto...

Страница 44: ...gaz reste activ e Mais si le contr le ne d tecte pas de flamme dans cette dur e de s curit TS sa fin l unit proc de un verrouillage et la vanne de gaz comme le dispositif d allumage sont coup s Si le...

Страница 45: ...t incorrecte La borne de terre du contr le le carter m tallique du br leur et la liaison de terre de l alimentation secteur doivent tre reli s ensemble Fonctionnement Quand une demande de chauffe est...

Страница 46: ...z 24 V 10 15 Charge de bobine 2 x 5 5 VA Connexion lectrique Syst me Molex de connexion de bobine ou option Bo tier de raccordement avec c ble int gr Position d installation Sol no de dans n importe q...

Страница 47: ...proved model of similar type must be used ELECTRICAL DIAGRAM SEE INSTRUCTION MANUAL FOR DETAILS ON HOW TO CONNECT THE ELECTRICAL COMPONENTS TRANSFORMER SCH MA LECTRIQUE REPORTEZ VOUS AU MANUEL D INSTR...

Страница 48: ...Transformer must be replaced a UL approved model of similar type must be used ionisation SCH MA DE C BLAGE CONTR LE FENWAL VANNE DE GAZ WHITE RODGERS SCH MA LECTRIQUE REPORTEZ VOUS AU MANUEL D INSTRUC...

Страница 49: ...replaced a UL approved model of similar type must be used Ignition Ionisation Ionisation SCH MA DE C BLAGE CONTR LE FENWAL VANNE DE GAZ DUNGS SCH MA LECTRIQUE REPORTEZ VOUS AU MANUEL D INSTRUCTIONS P...

Страница 50: ...50 www bromicheating com PI CES DE RECHANGE 1 2 3 4 5 9 10 11 24 8 12 23 6 22 7 17 13 16 19 20 15 13 14 19 White Rodger Honeywell...

Страница 51: ...20734 2620734 8 Enveloppe arri re 2620815 2620816 9 Ensemble de couvercle arri re 2620819 2620820 10 Br leur 2620822 2620822 11 Harnais de c blage ensemble d allumeur Honeywell 2620736 2620736 12 Memb...

Страница 52: ...____ Quel type de gaz est utilis Propane Gaz na turel Y a t il une exposition de l air salin ou une autre atmosph re corrosive ou chimique pour le les radiateur s Oui Non Est ce que l installation du...

Страница 53: ...naturel ou 11 pour du gaz propane au niveau de l ensemble de contr le du radiateur 3 Nettoyez l orifice 4 Fournissez une ventilation ad quate des sous produits 5 Remplacez la rampe 6 Augmentez la pres...

Страница 54: ...54 www bromicheating com ANNEXE A ZONE EN EXT RIEUR EXEMPLE 1 ZONE EN EXT RIEUR EXEMPLE 2...