8. TROUBLESHOOTING
IMPORTANT:
Repairs on the unit must be carried out by an authorised and licenced
person only. Contact the manufacturer or an approved service agent for any repairs
needed.
Symptom
Possible Cause(s)
Unit does not work A. No power supply
B. Main switch off
A. Check power supply
B. Turn on main switch
Cabinet
Temperature
Too High
A. Ambient temperature too high
B. Inadequate ventilation
C. Wall clearances below
minimum distance
D. Dirty condenser coil and filter
E. Ice build-up on evaporator coil
A. Relocate unit
B. Keep ventilation slots free
C. Adjust to minimum clearance
D. Clean
E. Check gaskets and set
temperature
Cabinet
Temperature
Too Low
A. Set temperature too low
A. Adjust set temperature
Water leak
A. Extreme operating condition
A. Relocate unit
Odour inside
cabinet
A. Cabinet dirty
A. Clean
Controller error
code
A. P1
B. P2
C. dA
A. Room probe failure
B. Evaporator probe failure
C. Door open or door switch
failure
Noisy
A. Unlevel surface
A. Relocate unit
Cleaning the Cabinet
• Remove the products and transfer to a suitable location prior to cleaning the inside
of the cabinet.
• Do not use any aggressive or abrasive cleaning agents.
• Never use a water hose or a high-pressure jet to clean.
• Do not use sharp or pointed objects for cleaning.
• Clean the inside and outside of the appliance with a clean damp cloth or with a
neutral cleanser.
• Dry all surfaces with a dry cloth.