HEATING INSTALLATION INSTRUCTIONS
TUBE SUSPENSION (SOLD SEPARATELY)
Heater must be installed according to the minimum installation clearances shown in these diagrams.
Dimensions shown in mm (inches)
CEILING MOUNTING
ANGLED
CEILING MOUNTING
FACE DOWN
The stated clearance to
combustible materials represents
surface temperatures of 65°C
(117°F) above room temperature.
Building material with a low
heating tolerance (such as plastic,
vinyl siding, canvas, tri-ply etc.)
may be subject to degradation
at a lower temperature. It is
the installer’s responsibility to
assure that adjacent materials are
protected.
MINIMUM DISTANCE BETWEEN
HEATERS MEASURED FROM
EDGE OF HEATER MUST BE AT
LEAST 500mm (20”)
WARNING
!
This heater MUST be permanently
installed by an authorised/
licenced person. Do not perform
maintenance, or carry out
installation or assembly procedure
while electrical power is switched
on. Wait 2 hours after switching
off the heater before handling.
!
WARNING - Outdoor
Installation
ENSURE CORRECT KIT IS
BEING USED FOR MARINE
ENVIRONMENTS.
REFER TO THE TABLE ON
THE PREVIOUS PAGE FOR
PART NUMBERS.