Bromic Part No. 1812020, 1812023, 1812026 and 1812028
Regulator Instructions
PLUMBING & GAS
•
Ensure regulator knob is fully wound in an ANTI-clockwise direction
•
SLOWLY open the cylinder valve
•
Adjust regulator knob until the low-pressure gauge shows a pressure of 100kPa
•
Close cylinder valve and observe the regulator gauges for one minute. If the gauges
show a drop in pressure there is a leak in the system. Check all connections (including
on the regulator) using a suitable leak testing solution and tighten any leaking
connections and repeat the leak test
•
Do NOT use the regulator if a leak is detected in the regulator. Contact the distributor
or Bromic immediately.
•
Do NOT use downstream equipment if a leak is detected. Contact the equipment
manufacturer immediately
•
If no leaks are detected then the regulator is ready for use.
4. FAULT FINDING
•
Check regulators for leaks and damage (especially the inlet o-rings) before every use.
Do NOT use regulators if a leak or damage is observed
•
Gauges not returning to zero reading or giving inconsistent readings should be
replaced
5. REGULATOR SPECS
Bromic Part No.
Gas.
Inlet Pressure
Max Outlet
Inlet Connection
1812020
Oxygen
20,000 kPa
1,000 kPa
Type 10
1812023
Acetylene
2,500 kPa
150 kPa
Type 20
1812026
LPG
2,550 kPa
400 kPa
Type 21
1812028
Argon
24,000 kPa
30 L/min
Type 10
27/02/2020 - V1.1
3