Bromic Heating 1812020 Скачать руководство пользователя страница 4

Bromic Part No. 1812020, 1812023, 1812026 and 1812028

Regulator Instructions

PLUMBING & GAS

•  

Ensure regulator knob is fully wound in an ANTI-clockwise direction

•  

SLOWLY open the cylinder valve

•  

Adjust regulator knob until the low-pressure gauge shows a pressure of 100kPa

•  

Close cylinder valve and observe the regulator gauges for one minute. If the gauges    

 

show a drop in pressure there is a leak in the system. Check all connections (including  

 

on the regulator) using a suitable leak testing solution and tighten any leaking  

 

 

connections and repeat the leak test

•  

Do NOT use the regulator if a leak is detected in the regulator. Contact the distributor  

 

or Bromic immediately.

•  

Do NOT use downstream equipment if a leak is detected. Contact the equipment  

 

 

manufacturer immediately

•  

If no leaks are detected then the regulator is ready for use.

4.     FAULT FINDING

•  

Check regulators for leaks and damage (especially the inlet o-rings) before every use.  

 

Do NOT use regulators if a leak or damage is observed

• 

Gauges not returning to zero reading or giving inconsistent readings should be  

 

 replaced

5.     REGULATOR SPECS

Bromic Part No.

Gas.

Inlet Pressure

Max Outlet

Inlet Connection

1812020

Oxygen

20,000 kPa

1,000 kPa

Type 10

1812023

Acetylene

2,500 kPa

150 kPa

Type 20

1812026

LPG

2,550 kPa

400 kPa

Type 21

1812028

Argon

24,000 kPa

30 L/min

Type 10

27/02/2020 - V1.1

3

Отзывы: