B102243-2-0615
Page 20
10” SS
FLEX LINE
34” SS
FLEX LINE
VALVE
GRILL
VALVE
Attach the regulator and hose
assembly to the brass “tee”.
Reconnect the assembly to the
cylinder. Use wrenches to hold and
tighten the joint between the hose and
“tee”.
3/4”
TEE
Gas Type
Your Broilmaster Side Burner is factory equipped for LP gas
and must be converted for use with Natural gas grills. Never
use liquid propane gas with a grill designed for natural gas,
or natural gas with a grill designed for liquid propane gas.
The type gas required for your grill can be determined from
its product identification label. Questions regarding differ-
ent types of gases should be directed to your gas company.
1. Remove burner caps
.
2. Remove flame spreader.
3. Use a 7 mm nut driver or socket wrench to remove the
1.15mm LP orifice and replace it with the 1.6mm Natural
gas orifice supplied (sizes are stamped on each orifice).
4. Replace the flame spreader and caps.
5. Remove plastic knob on the control valve by inserting small
phillips screwdriver through hole at base of knob. Loosen
set screw by turning counter-clockwise. Remove knob from
control valve. The control valve will have a set screw in the
center of stem. Using a small standard screwdriver turn set
screw in center of valve stem half turn counterclockwise.
VALVE STEM
LPG
NAT
VALVE CONVERSION
ADJUSTMENT
SCREW
6. Apply soapy solution to test for leaks around the set screw.
If a leak is found, turn screw clockwise until bubbles cease.
Important: Place conversion label adjacent to serial number
label under Side Burner.
NATURAL GAS CONVERSION
PROPANE GAS CONNECTION
Содержание DPA150-1
Страница 8: ...B102243 2 0615 Page 8 CONNECT IGNITOR LEADS GROUND WIRE B072684 1 ...
Страница 12: ...B102243 2 0615 Page 12 BATTERY PLACEMENT BATTERY AA B076539 1 ...
Страница 15: ...B102243 2 0615 Page 15 INSTALL GRATE ...
Страница 31: ...B102243 2 0615 Page 31 GRILL MAINTENANCE HISTORY Date Maintenance Performed ...