Page 22
B100691-4-0606
T
ROUBLESHOOTING
Although the manufacturer has attempted to ensure that your grill will operate properly and satisfactorily,
sometimes problems do arise. The following troubleshooting guide lists several possible problems and their
probable cause and solution.
Problem
Cause
Solution
Burner will not
light.
Gas injector not inserted in ven-
turi tube.
Realign/engage gas injector with the venturi
tube.
Clogged gas injector.
Remove gas injector from gas control assem-
bly and clean.
Obstruction in gas line.
For propane models, ensure gas valve on cyl-
inder is OFF. Remove flexible hose and blow
out any debris.
Spider webs in venturi tubes.
Clean venturi tubes. See Maintenance Section.
Misalignment of collector box and
burner.
Position electrode properly. Clean collector
box.
Out of gas.
Refill LP gas cylinder. If natural model, turn
on gas at source.
Dead battery.
Replace with AA Alkaline battery.
Inadequate grill
temperature.
Poor combustion.
Adjust air shutter.
Misalignment of venturi tube and
gas injector.
Realign/engage gas injector with the venturi
tube.
Inadequate gas pressure.
Contact gas supplier for assistance.
Incorrect orifice/valve setting.
Refer to gas conversion instructions in this
manual.
Flames blow out.
Cold grill.
Preheat grill at least 5 minutes on HI with the
grill lid closed.
Misalignment of burner tube and
gas injector.
Realign/engage gas inector with the burner
tube.
Poor combustion.
Adjust the air shutter.
Extreme wind.
Turn or shield grill.
Yellow flames.
Air shutter improperly set.
Open air shutter. See maintenance Section.
Spider webs in venturi tubes.
Clean venturi tubes. See Maintenance Section.
Seasoning salts on burner.
Clean by washing burner with mild detergent.
Oil film on burner.
Allow burner to operate on HI for 10-15 min-
utes.