Brocade VDX 8770-8 Hardware Reference Manual

17

53-1002564-01

Unpacking and installing the Brocade VDX 8770-8

2

1.

Unpack the Brocade VDX 8770-8.

a.

Cut the bands that encircle the packaging.

b.

Slide the upper portion of the cardboard shipping box up off the pallet and shipping tray. 

NOTE

The Brocade VDX 8770-8 packaging incorporates a wood pallet and brackets. The chassis sits 
on top of a corrugated cardboard shipping tray.

c.

Save the packing materials for use when returning a chassis.

d.

Leave the chassis on top of the shipping tray and pallet if the chassis must be transported 
to the installation location.

2.

Use a pallet jack or other assisted lift to transport the new chassis to the installation area. 
Doorways must be wider than 36 in. (91 cm) to accommodate the chassis.

3.

Using the rack mount instructions, install the rack components in the rack and mounting 
flanges on the chassis. The rack mount kit and instructions may be shipped separately from 
the chassis.

4.

Remove the accessory kit (cardboard box), packing foam, and antistatic plastic from the 
chassis and set them aside.

5.

Remove the foam inserts around the base of the chassis.

6.

Use a lift to raise the chassis to the correct level. If installing the chassis in a cabinet, follow the 
instructions provided by the rack kit manufacturer.

7.

If applicable, lock the wheels of the lift.

8.

Ensure that the chassis is oriented so that the port side (front) has access to intake air.

9.

Gently slide the chassis onto the final installation surface, ensuring that it remains supported 
during the transfer.

10. Before you apply power to the chassis, you can install the line cards to speed up your 

installation. Complete the following steps for each linecard you install before installing the next 
line card. Use ESD procedures to protect the line cards from static damage.

a.

Remove the filler panel by pulling the release pins outward and moving the slides toward 
the center of the panel, then pulling the panel out using the tabs on the ends.

b.

Set the panel aside and retain for future use.

c.

Carefully remove the line card from it’s shipping box.

d.

Open the plastic anti-static pouch and remove the line card. Handling the card by the 
edges, inspect it for damage.

e.

Align the edges of the module pan with the slot guides and carefully and firmly slide the 
module all the way into the slot.

f.

Grasp the ejectors simultaneously and rotate them away from the center of the module to 
fully seat the module in the slot.

g.

Using the Philliips screwdriver, tighten the captive screws at both ends of the module.

h.

Repeat 

step a

 through 

step g

 for each additional line card you are installing.

Содержание VDX 8770-8

Страница 1: ...53 1002564 01 15 October 2012 Brocade VDX 8770 8 Hardware Reference Manual...

Страница 2: ...sing from the information contained in this book or the computer programs that accompany it The product described by this document may contain open source software covered by the GNU General Public Li...

Страница 3: ...Brocade VDX 8770 8 Hardware Reference Manual 3 53 1002564 01...

Страница 4: ...4 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 01...

Страница 5: ...hnical help xv Document feedback xv Chapter 1 Brocade VDX 8770 8 Overview In this chapter 1 Brocade VDX 8770 8 features 1 Brocade VDX 8770 8 hardware components 2 Port side of the Brocade VDX 8770 8 3...

Страница 6: ...ocade VDX 8770 8 25 Customizing a host name 25 Customizing a chassis name 26 Setting the date and time 26 Understanding time zones 26 Understanding time synchronization 27 Synchronizing local time usi...

Страница 7: ...t 49 Time and items required 50 Removing a line card 50 Replacing a line card 51 Management module removal and replacement 52 Time and items required 52 Faulty management module indicators 53 Recordin...

Страница 8: ...ndix 73 General specifications 73 System architecture 73 System size and weight 74 System component weights 74 Ethernet port supported optics 75 Power cords 76 Power cord notice 78 Power cord notice J...

Страница 9: ...module 44 Figure 9 Removal and replacement of the cable management comb 49 Figure 10 Removal and replacement of a line card 48x10G card shown 51 Figure 11 Removal and replacement of the management mod...

Страница 10: ...viii Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 01...

Страница 11: ...38 Table 11 Management module LED descriptions 39 Table 12 Switch fabric module LED descriptions 41 Table 13 Output for show environment power command 43 Table 14 Power supply LED descriptions 43 Tabl...

Страница 12: ...x Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 01...

Страница 13: ...ription of its features Chapter 2 Installation of the Brocade VDX 8770 8 describes how to install set up and power on the Brocade VDX 8770 8 Chapter 3 Logging In and Configuring the Brocade VDX 8770 8...

Страница 14: ...xt to enter at the GUI or CLI italic text Provides emphasis Identifies variables Identifies paths and Internet addresses Identifies document titles code text Identifies CLI output Identifies syntax ex...

Страница 15: ...ion ATTENTION An Attention statement indicates potential damage to hardware or data CAUTION A Caution statement alerts you to situations that can be potentially hazardous to you or cause damage to har...

Страница 16: ...cade website and are also bundled with the Network OS firmware Other industry resources For additional resource information visit the Technical Committee T11 Web site This Web site provides interface...

Страница 17: ...as shown here The serial number label is located on the port side of the chassis on the lower right side and directly above the cable management comb In addition the s show chassis command displays th...

Страница 18: ...are Reference Manual 53 1002564 01 documentation brocade com Provide the title and version number and as much detail as possible about your comment including the topic heading and page number and your...

Страница 19: ...over a global network that integrates both static and cloud based resources The Brocade VDX 8770 8 runs on the Brocade Network Operating System Network OS v3 0 0 For details about Network OS refer to...

Страница 20: ...ng the front of the equipment rack and consists of the following Eight slots for hot swappable line cards that can be configured in a single chassis delivering up to 384 10 Gbps Ethernet ports or 48 4...

Страница 21: ...port side of the Brocade VDX 8770 8 FIGURE 1 Port side of the Brocade VDX 8770 8 sample configuration 1 Line cards L1 through L4 left to right 6 Intake Vent 2 Cable management comb 7 Management modul...

Страница 22: ...of the Brocade VDX 8770 8 The following figure shows a sample configuration of the nonport side view of the Brocade VDX 8770 8 FIGURE 2 Nonport side of the Brocade VDX 8770 8 sample configuration 1 Fa...

Страница 23: ...to the standby module will occur in case of active module failure but the standby module will go through a cold recovery in which all system components are reset This will disrupt traffic on the chas...

Страница 24: ...Fabric Services for FCoE VN port devices ISL port service to form VCS cluster Multipath support for FCoE traffic FCoE over standard LAGs Cloud Model multiple Enodes behind same physical or logical po...

Страница 25: ...nagement OAM Distributed configuration management DCMd Licensing VCS licensing available multi node license for more than two nodes enables Ethernet Fabric functionality FCoE licensing enables FCoE Fo...

Страница 26: ...8 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 01 Software features 1...

Страница 27: ...lone unit For rack mount installation instructions refer to the appropriate manual as described in the following table Table 2 describes the main installation and setup tasks the estimated time requir...

Страница 28: ...0 8 in the rack 30 minutes Installing power cables and powering on the Brocade VDX 8770 8 20 minutes Power cables provided in the Brocade VDX 8770 8 accessory kit Establishing a serial connection logg...

Страница 29: ...removed to provide an RJ45 style connector Wrist strap ESD grounding strap Ground lug kit SFP extraction tool kit China RoHS guide Cable management comb Brocade branded USB device Power cord retainer...

Страница 30: ...ecured to provide stability in the event of an earthquake and that the equipment does not exceed the rack s weight limits 2 Ensure that dedicated electrical branch circuits with the following characte...

Страница 31: ...tions Power for the Brocade VDX 8770 8 can be supplied with either AC or DC based 3000 watt power supplies The Brocade VDX 8770 8 has room for up to eight 12V DC output power supplies Table 3 shows th...

Страница 32: ...wer demand at idle blades enabled no optics ports disabled Watts Nominal power demand blades enabled optics 50 line rate random packets Watts Maximum power demand blades enabled optics traffic present...

Страница 33: ...where the operating ambient temperature might exceed 40 C 104 F Table 7 lists the environmental operating ranges for the Brocade VDX 8770 8 The requirements for non operating conditions are also prov...

Страница 34: ...M installed in either slot S3 or slot S4 The line card slots L1 through L8 can be filled with either 48x1G 48x10G or 12x40G line cards Unused slots must be filled with the correct filler panels to mai...

Страница 35: ...chassis in a cabinet follow the instructions provided by the rack kit manufacturer 7 If applicable lock the wheels of the lift 8 Ensure that the chassis is oriented so that the port side front has ac...

Страница 36: ...hassis DANGER Use the supplied power cords Ensure the facility power receptacle is the correct type supplies the required voltage and is properly grounded D004 1 Connect the AC or DC power cords to th...

Страница 37: ...8 Saving your changes 29 Verifying correct operation 29 Backing up the configuration 30 Connecting network devices 30 Installing transceivers and attaching cables 31 Managing cables 32 Creating Brocad...

Страница 38: ...abric is self forming When two or more VCS enabled switches with unique rbridge ids are connected the fabric is automatically created and the switches discover the common fabric configuration The fabr...

Страница 39: ...e VDX 8770 8 to connect the serial port on the active management module to a computer workstation If the serial port on the workstation or terminal device is DB9 instead of RJ 45 remove the adapter on...

Страница 40: ...cation Network OS 8770HOST 8770HOST console login admin Password WARNING The default password of admin and user accounts have not been changed Welcome to the Brocade Network Operating System Software...

Отзывы: