A-6

Содержание SilkWorm 2400

Страница 1: ...SilkWorm 2400 Hardware Reference Manual Publication Number 53 0001533 01...

Страница 2: ...service marks of and are used to identify products or services of their respective owners Notice This document is for informational purposes only and does not set forth any warranty express or implie...

Страница 3: ...on is applicable Chapter 2 Installation is applicable except for the following which are not applicable Option of one power supply Additional racking information available from Hewlett Packard Chapter...

Страница 4: ......

Страница 5: ...Text CE Statement The standards compliance label on the SilkWorm 2400 Fibre Channel Switch contains the CE mark which indicates that this system conforms to the provisions of the following European C...

Страница 6: ......

Страница 7: ...rations 2 4 Rackmount Safety Guidelines 2 4 Installing Slide Assembly Optional 2 4 Standalone 2 6 Fiber Channel Cable Connections 2 6 Serial Port Connection 2 7 Serial Cabling and Emissions Requiremen...

Страница 8: ...2 Optical Port Specifications A 3 Copper GBIC Module A 3 Environmental Specifications A 4 Dimensions A 4 Rack Mount Dimensions A 4 Table Top Dimensions A 4 Weight A 4 Power Supply A 5 Appendix B Switc...

Страница 9: ...al includes Field Technicians How this Manual is Organized The following table describes how the manual is organized FOR INFORMATION ON SEE Switch features and system components Chapter 1 Introduction...

Страница 10: ...Channel Standards For detailed information on the Fibre Channel standards see the Fibre Channel Association web site http www fibrechannel com Revision History FABRIC OPERATING SYSTEM VERSION DATE DO...

Страница 11: ...nel server and storage nodes Figure 1 1 shows the front view of the SilkWorm 2400 switch Ports are numbered sequentially starting with zero for the left most port The switch face plate includes a silk...

Страница 12: ...B sec The latency may differ when the destination or device is a loop Automated congestion management Virtual channels lets the switch use sophisticated congestion management techniques that are perfo...

Страница 13: ...s visible from the front panel giving a quick visual check of the GBIC s status and activity GBIC modules supported are the ShortWave Length SWL and LongWave Length LWL fiber optics and Copper Cu vers...

Страница 14: ...ould remain in place if no fiber optic cable is connected to the port Figure 1 3 shows a GBIC module Figure 1 3 Long Wavelength Laser LWL fiber optic GBIC module Passive Copper GBIC Module The Copper...

Страница 15: ...SilkWorm 2400 Hardware Reference Manual 2 1 2 INSTALLATION 2 This chapter covers the following Unpacking the switch Selecting a location and mounting method Setting up connections...

Страница 16: ...ature Guides if a feature s is ordered Rubber mounting feet Save packing materials in case you need to return the switch Refer to Appendix B Switch Support for information on contacting Brocade Coolin...

Страница 17: ...within its ranges A green power on indicator light is located above the power switch in the power supply module NOTE The SilkWorm 2400 is available in two models The 2401 includes one power supply uni...

Страница 18: ...talled in the rack has a reliable ground connection Do not rely on connection to a branch circuit such as power strips Route and support the power cord to ensure that the switch moves freely on its sl...

Страница 19: ...stationary slide portions to the front and rear rack rails 2 Engage the slide mounted on the switch with the stationary slide portion mounted on the rack and press toward the rear until the latches e...

Страница 20: ...transfer rate as shown in Table 2 1 NOTE The switch is not designed to interoperate with devices using an Open Fibre Control optical interface Table 2 1 Cabling Connections CABLE TYPE CABLE SPECIFICA...

Страница 21: ...he protective plug from the GBIC Do not force the fiber optic plug into the GBIC module as you may damage the connector the GBIC module or both Make certain the fiber surface is clean free of dust or...

Страница 22: ...UTION The serial port is intended for initial configuration of the IP address or disaster recovery only and not for regular maintenance Serial Cabling and Emissions Requirements The switch uses a stan...

Страница 23: ...dress subnet mask and gateway address 4 Copy the IP Address to the label provided for future reference Resetting Factory Defaults In the event that a user changes a password and forgets it the passwor...

Страница 24: ...message Passed is displayed via the Telnet After the switch completes the POST the port module returns to a steady state from the flashing states shown during the tests If a yellow port module light...

Страница 25: ...Hardware Reference Manual 3 1 3 DIAGNOSTICS 3 This chapter discusses troubleshooting and diagnostic testing It includes these sections Diagnostic Overview Diagnostic Command Summary Status and Activi...

Страница 26: ...tages of POST and indicates that the CPU is not able to bring up the operating environment Should this condition occur the switch should be returned for repair If a serial link is connected to the Sil...

Страница 27: ...t camTest Port Loopback Test portLoopbackTest Cross Port Test crossPortTest Spin Silk Test spinSilk SRAM Data Retention Test sramRetentionTest CMem Data Retention Test cmemRetentionTest Switch Online...

Страница 28: ...connection This could indicate a loopback cable is installed the fabric is segmented a E port connection to another switch cannot be completed and the switches cannot form a fabric or the SilkWorm has...

Страница 29: ...Link initialization receiver transmitter negotiation to bring connected ports online 7 Fabric analysis the switch checks for ports connected to other Fabric elements If there are other Fabric elements...

Страница 30: ...Chapter 3 Diagnostics 3 6...

Страница 31: ...ory switch System processor Superscalar 33 Mhz Intel i960RP Number of Fibre Channel Ports 8 ports Fibre Channel port speed 1 0625 Gbps full duplex Modes of operation Fibre Channel Class 2 service and...

Страница 32: ...SAFETY EMC Canada CSA 22 2 No 950 Third Edition CSA C108 8 Class A United States UL 1950 Third Edition FCC Part 15 Class A Japan EN60950 A1 A2 A3 A4 A11 VCCI Class A International EN60950 A1 A2 A3 A4...

Страница 33: ...g the need for physical shutters The optical GBIC uses the duplex SC connector scheme Copper GBIC Module The Copper CU GBIC module is based on the High Speed Serial Data Connection HSSDC interface sta...

Страница 34: ...Top Dimensions H 43 4 mm 1 86 in W 428 6 mm 16 88 in D 450 0 mm 17 72 in Weight 17 lbs Table A 4 SilkWorm 2400 Environmental Specifications Specification Value Temperature operating 0 C to 40 C Temper...

Страница 35: ...mate connector It provides facilities to support a dual redundandant power supply configuration in which the supplies are hot swappable An integral on off switch input filter and power indicator are...

Страница 36: ...Appendix A 6...

Страница 37: ...er is also the correct source for switch repairs or for supplying spare components Support Tool Included in the switch software is a command that will provide a display of a variety of information tha...

Страница 38: ...Appendix B 2...

Страница 39: ...eded the messages are overwritten in a first in first out sequence The errShow command displays all detected errors The output provides additional information over the front panel display The followin...

Страница 40: ...CR 3 Scroll through error log if no errors encountered the command returns No Error Figure E 1 errShow Command Example switch admin errShow Error 02 0x103dc470 tSwitch Apr 9 10 41 06 4 Error SENSOR F...

Страница 41: ...installation attaching rubber feet 2 6 complete install 2 1 cooling requirements 2 2 power requirements 2 3 rackmount considerations 2 4 site location 2 3 unpacking the switch 2 2 introduction 1 1 ipA...

Страница 42: ...Index 2 Index...