ELECTRICAL TIPS
COMPLAINT
CAUSE
REMEDY
Probe Fault
1. Open probe circuit
2. Probe wires reversed
3. Probe changes more than
100°F in two seconds.
1. Replace Probe
2. Correct wiring
3. Turn power switch OFF.
Contact service person.
HI Temperature
Oil Temperature has reached
415°F/213°C.
1.Turn power switch OFF.
Contact service person.
Internal Fault
An internal fault has been dis-
covered in the control.
1.Turn power switch OFF.
Contact service person.
Heater Fault
- appears if
the oil temperature is less
than 250°F/121°C and the
temperature does not raise
at least 6°F/4°C during any
6 minute time period.
1. Gas valve switch is off.
2. No gas present.
3. Oil Temperature not rising
properly.
1. Turn gas valve switch on.
2. Turn main gas valve on.
3. Turn power switch OFF.
Contact service person.
C1 Fault
(Electric Fryers)
This will appear if power is
present at the output of C1
contactor after one second
when the power is turned off.
1.Turn power switch OFF.
Contact service person.
broaster.com Manual #17403 5/14 Rev 9/14
Содержание 1600
Страница 2: ......
Страница 4: ......
Страница 9: ......
Страница 11: ......
Страница 13: ......
Страница 14: ...4 GETTING TO KNOW YOUR BROASTER PRESSURE FRYER 4 1 Model 1600 broaster com Manual 17269 8 13 ...
Страница 15: ...4 2 Model 1800 broaster com Manual 17269 8 13 ...
Страница 19: ......
Страница 23: ......
Страница 41: ......
Страница 47: ......
Страница 49: ......
Страница 56: ......
Страница 57: ...The Broaster Company 2855 Cranston Road Beloit WI 53511 3991 608 365 0193 broaster com ...