XB110HL Installation Guide
Page 5
3
4
1
2
New Construction Installation
5
Connect Wires and Install Knockout Plate
• Run 120VAC electrical wiring to the installation location.
• Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
• Connect wires as shown in wiring diagram.
• Do not use a dimmer switch to operate the light.
Screw from
Parts Bag
Attach cable clamps to Knockout
Plate. Knockout Plate mounts to
outside of Housing and may be
oriented as desired.
Connect wires
Fan
Light
LIGHT
WHT
MANUAL-ON
GRD
WHT
BLK
GRD
WHT
BLK
RED
120 VAC
LINE IN
MULTI-FUNCTION
WALL SWITCHES
SENSOR/CONTROL
LIGHT
NIGHT-LIGHT
BLU
NIGHT
LIGHT
RED
WHT
BLK
RED
FAN
SENSOR/
CONTROL
BLK
WHT
BRN
BLK
RED
ORG
14/3
(IF ALL
WALL SWITCH
OPTIONS
ARE USED)
14/3
KNOCKOUT
PLATE
LIGHT RECEPTACLE WIRES
FAN RECEPTACLE
WIRES
MULTI-FUNCTION
WALL SWITCHES
(purchase separately)
120 VAC
LINE IN
MANUAL - ON
SWITCH
BOX
LIGHT
NIGHT
LIGHT
SENSOR / CONTROL
BLACK
WHITE
ORANGE
RED
BLUE
GROUND
(green or bare)
BROWN
RECEPTACLES
• See OPERATION section on page
12 for details.
• SENSOR/CONTROL switch turns
humidity control on for automatic
operation and off for fan cleaning
and maintenance purposes.
• MANUAL-ON switch directly turns
fan on/off.
• MANUAL-ON switch is not required
to manually turn fan on (see page
10).
• SENSOR/CONTROL switch may
be located where it is not easily
accessed for everyday usage; it
may need to be labeled and located
where it can’t be turned on without
being seen from fan to comply with
local and national codes.