background image

SWITCH BOX

GROUNDED

WIRE/CLIP DETAIL

UNIT

WHITE

RED

120 VAC LINE IN

ON/OFF

SWITCH

BLACK

GROUND

SENSOR

FAN

UNIT

GROUND

WHITE

BLACK

BLACK

RED

BLACK

ON/OFF SWITCH

RED

WHITE

WHITE

GROUND

WIRING OPTION #2

Allows fan to operate in automatic mode or to be turned ON
independent of humidity sensing control.

WIRING COVER

BLACK

SWITCH BOX

120 VAC

LINE IN

OFF (AUTO)

ON (MANUAL)

ON

(MANUAL)

OFF (AUTO)

WIRE THE FAN 

(CONT'D)

SENSOR

FAN

BLACK

RED

120 VAC

LINE IN

UNIT

BLACK

WHITE

GROUND

WIRING OPTION #3

Fan circuit will always be in automatic mode.

ATTACH THE GRILLE

1. Squeeze grille springs

together and insert
springs into slots in
blower assembly.

2. Push grille up against

ceiling.

3. Turn on power and check

fan operation.

SENSOR OPERATION

The ULTRA-SENSAIRE

® 

fan uses a sophisticated humidity sen-

sor that responds to: (a) rapid to moderate (user-adjustable)
increases in humidity or (b) humidity above a user-adjustable
set-point (50%-100% Relative Humidity). The humidity sensor
may occasionally turn the fan ON when environmental condi-
tions change. If the fan continuously responds to changing
environmental conditions, "SENSITIVITY" adjustment may be
required.

MANUAL ON WITH TIMED OFF

The ULTRA-SENSAIRE

®

 fan has an additional operation fea-

ture. For odor or vapor control, the fan can be energized by
cycling the power switch. Once the fan has been energized in
this manner, it will remain on for the user-adjustable "TIMER"
period (approx. 5 to 60 minutes). This period is factory-set for
approximately 20 minutes.

To manually energize the fan:

1. If fan power switch is already ON, proceed to Step 2; other-

wise, turn power switch ON for more than 1 second.

2. Turn fan power switch OFF for less than 1 second.

3. Turn fan power switch back ON and fan will turn ON.

USE AND CARE

SENSITIVITY ADJUSTMENT
The "SENSITIVITY" has been factory set for most shower appli-
cations. However, if the fan is in a tub area or is being used for
dampness control, the "SENSITIVITY" may need to be increased
toward maximum ("MAX."). If the control is responding too of-
ten to changing environmental conditions, movement toward
less ("MIN.") "SENSITIVITY" may be required.
To adjust the "SENSITIVITY":
1. Disconnect power at service entrance.
2. Through the grille, locate the screwdriver slot marked "SEN-

SITIVITY".

3. Using a small, flat-blade screwdriver, carefully rotate the

"SENSITIVITY" adjustment toward "MAX." or "MIN."

4. Turn on power and check operation by turning on the shower

or other humidity source until the fan turns on.

5. Repeat above steps if necessary.

TIMER  ADJUSTMENT
The ULTRA-SENSAIRE

®

 fan has a "TIMER" that can be ad-

justed from 5 to 60 minutes (factory-set at approx. 20 minutes).
This "TIMER" controls the length of time that the fan remains
ON (a) after the sensor has stopped sensing a rise in humidity
and the humidity level is below the user-adjustable set-point or
(b) after being energized by cycling the power switch.
To adjust the "TIMER":
1. Disconnect power at service entrance.
2. Through the grille, locate the screwdriver slot marked

"TIMER".

3. Using a small, flat-blade screwdriver, carefully rotate the

"TIMER" adjustment to desired setting (from 5 to 60 min-
utes).

4. Check operation by cycling the power switch as instructed

under "MANUAL ON WITH TIMED OFF" or by turning on a
humidity source until the fan turns on.

5. Turn humidity source off and time the unit.
6. Repeat above steps if necessary.

WARNING

BEFORE CLEANING, SERVICING OR ADJUSTING THE
UNIT, SWITCH POWER OFF AT SERVICE PANEL. LOCK
SERVICE PANEL TO PREVENT POWER FROM BEING
SWITCHED ON ACCIDENTALLY.

3

Содержание ULTRA-SENSAIRE HS110UE

Страница 1: ...I Ground Fault Circuit Interrupter protected branch circuit 8 Never place a switch where it can be reached from a tub or shower 9 This unit must be grounded CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for ceiling installation only DO NOT MOUNT THIS PRODUCT IN A WALL 3 To avoid humidity sensor damage motor b...

Страница 2: ...ew 4 Plug wiring connectors into their receptacles SENSOR FAN BLACK BLACK RED WHITE GROUND 120 VAC LINE IN UNIT BLACK WHITE SWITCH BOX ON AUTO OFF MANUAL ON OFF SWITCH GROUND WIRING OPTION 1 Allows fan to operate in automatic mode or manual on with timed off mode for odor control by cycling ON OFF switch Allows fan circuit to be turned OFF when desired 3 Hang housing from nails Use measur ing guid...

Страница 3: ...tch OFF for less than 1 second 3 Turn fan power switch back ON and fan will turn ON USE AND CARE SENSITIVITY ADJUSTMENT The SENSITIVITY has been factory set for most shower appli cations However if the fan is in a tub area or is being used for dampness control the SENSITIVITY may need to be increased toward maximum MAX If the control is responding too of ten to changing environmental conditions mo...

Страница 4: ...om state to state This warranty supersedes all prior warranties To qualify for warranty service you must a notify Broan NuTone at the address stated below or telephone 1 800 637 1453 b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date KEY PAR...

Отзывы: