background image

INST

ALLA

TION 

AND USE & CARE INSTR

UCTIONS

 

INST

ALLA

TION

6

SWITCH BOX

LIGHT

FAN

DUAL CONTROL

(purchase separately)

WHITE

BLACK

RED
GROUND
(bare)

WIRING PLATE

120 VAC LINE IN

RECEPTACLE

(FAN)

RECEPTACLE

(LIGHT)

WIRING DIAGRAM 

7.  Connect wiring.

Connect power cable to housing with appropriate 

UL approved connector (not included). Make wiring 

connections as shown in “Wiring Diagram” section. Re-

install wiring panel and secure with screw from parts bag.

9.  Connect 4-in. round duct.

 

Pull existing ducting through housing discharge 

opening. 

 

Attach and tape ducting to duct connector. 

 

Push connector/ducting back through opening. 

 

Engage tabs and secure with screw from parts 

bag.

Install blower. Finish ceiling, then 

install grille.

See Steps 9 & 10 on Page 5.

8.  Mount fan to ceiling structure.

Mount housing to ceiling structure with standard 

drywall or wood screws (not included) in locations 

shown.

*

Center hole optional.

1

2

3

4

TABS

1101892D

Содержание ROOMSIDE AER110LBN

Страница 1: ...ATION AND USE CARE INSTRUCTIONS INSTRUCTIONS D INSTALLATION D UTILISATION ET D ENTRETIEN INSTRUCCIONES DE INSTALACI N USO Y CUIDADO English See page 2 Fran ais Voir page 7 Espa ol Consulte la p gina 1...

Страница 2: ...ccordance with all applicable codes and standards including fire rated construction codes and standards Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney...

Страница 3: ...eep duct runs short 4 IN ROUND DUCT ALL INSTALLATIONS Start here IMPORTANT The ducting from this fan to the outside of the building has a strong effect on the air flow noise and energy use of the fan...

Страница 4: ...g Push connector through opening from inside of housing Engage tabs and secure with screw from parts bag 6 Mount housing to ceiling structure Make sure bottom of housing will be flush with finished ce...

Страница 5: ...nd wiring in place 6 Fold mounting ears flat against housing RETROFIT 2 10 in 9 in JOIST 1 10 Finish ceiling then install grille Attach MOUNTING PLATE to housing with 2 SCREWS using the GRILLE BACKETS...

Страница 6: ...ng Diagram section Re install wiring panel and secure with screw from parts bag 9 Connect 4 in round duct Pull existing ducting through housing discharge opening Attach and tape ducting to duct connec...

Страница 7: ...is ceux concernant la protection contre les incendies Un certain volume d air est n cessaire aux appareils combustible pour assurer la bonne combustion et l vacuation des gaz par le conduit de fum e c...

Страница 8: ...iser un trac de conduits court CONDUIT ROND DE 4 po TOUTES INSTALLATIONS D but IMPORTANT Le conduit reliant l appareil l ext rieur influe fortement sur le d bit d air le bruit et la consommation d ner...

Страница 9: ...tir de l int rieur du bo tier Placer les languettes et fixer le raccord avec des vis du sac de pi ces 6 Fixer le bo tier la charpente du plafond Veiller ce que le bas du bo tier affleure la surface fi...

Страница 10: ...Plier les oreilles de montage plat sur le bo tier REMPLACEMENT 2 10 po 9 po SOLIVE 1 10 Finir le plafond puis installer la grille Fixer la PLAQUE DE FIXATION au bo tier l aide des SUPPORTS DE GRILLE i...

Страница 11: ...et le fixer avec des vis du sac de pi ces 9 Raccorder le conduit rond de 4 po Tirer le conduit existant travers l ouverture d vacuation du bo tier Joindre le conduit au raccord et fixer le joint avec...

Страница 12: ...mas de construcci n espec ficos sobre protecci n contra incendios Es necesario suficiente aire para que se lleve a cabo una combusti n y una extracci n adecuadas de los gases a trav s del tubo de humo...

Страница 13: ...arado O Mantenga cortos los tramos de conductos 4 pulg 10 cm CONDUCTO REDONDO TODAS LAS INSTALACIONES Comience aqu IMPORTANTE Los conductos desde este ventilador hacia el exterior del edificio tienen...

Страница 14: ...erior de la cubierta Enganche las leng etas y f jelas con el tornillo incluido en la bolsa de piezas 6 Monte la cubierta en la estructura del cielo raso Aseg rese de que la parte inferior de la cubier...

Страница 15: ...as de montaje planas contra la cubierta CONVERSI N 2 10 pulg 26 7 cm 9 pulg 24 8 cm VIGUETA 1 10 Termine el cielo raso y a continuaci n instale la rejilla Fije la PLACA DE MONTAJE a la cubierta con do...

Страница 16: ...lo con el tornillo de la bolsa de piezas 9 Conecte el conducto redondo de 4 pulg 10 cm Pase el conducto existente por la abertura de descarga de la cubierta Fije y pegue con cinta los conductos al con...

Отзывы: