background image

Page 3

VENTILATION FAN / LIGHT            MODEL  QTXE150FLT

1b.  Mount housing anywhere between 

trusses, joists, or 

I

-joists using hanger 

bars.

Sliding hanger bars are provided to allow for accurate positioning 

of housing anywhere between framing. They can be used on all 

types of framing (

I

-joist, standard joist, and truss construction) 

and span up to 24”.
Attach the MOUNTING CHANNELS to the housing using the 

SCREWS supplied. 

Extend HANGER 

BARS to the width of 

the framing.
Hold housing in place 

so that bottom edge of 

housing will be flush 

with finished surface 

of ceiling.  For 1/2” 

thick ceiling material, 

position bottom of 

each mounting flange 

flush with bottom of 

joist.

OR

INSTALLATION

1a. Mount 

housing to 

joist.

 

Hold housing 
in place so that 
bottom edge 
of housing will 
be flush with 
finished surface 
of ceiling. For 
1/2” thick ceiling 
material, position bottom of each mounting flange flush 
with the bottom of joist. The housing mounts with four (4) 
screws or nails. Screw or nail housing to joist through low-
est holes in each mounting flange,  then through highest 
holes. NOTE: Mounting to 

I-JOIST

 (shown) requires use 

of 

SPACERS

 (included) between the highest hole of each 

mounting flange and the I-joist.

2. Attach 

damper/duct 

connector.

3. Install 

6-inch round 

ductwork.

 

Connect 6-inch 

round ductwork 

to damper / duct 

connector. Run 

ductwork to a roof 

cap or wall cap. 

Tape all ductwork 

connections 

to make them 

secure and air tight.

SPACER

(use for 

mounting 

to I-Joist)

TOP AND BOTTOM FLANGES 

REMAIN OUTSIDE OF HOUSING

I-JOIST

SCREW 

FROM 

PARTS BAG

INSERT

TAB INTO 

SLOT IN 

HOUSING

To ensure a noise-free 

mount: Secure hang-

ing bars together with 

SCREWS and use a 

pliers to crimp mount-

ing channels tightly 

around hanger bars.

Содержание QTXE150FLT

Страница 1: ...es all prior warranties and is not transferable from the original consumer purchaser No Other Warranties This Limited Warranty contains the Company s sole obligation and your sole remedy for defective...

Страница 2: ...A COOKING AREA ROOF CAP with built in damper WALL CAP with built in damper 6 IN ROUND ELBOWS 6 IN ROUND DUCT FAN HOUSING Seal gaps around housing Seal duct joints with tape Keep duct runs short INSULA...

Страница 3: ...ng will be flush with finished surface of ceiling For 1 2 thick ceiling material position bottom of each mounting flange flush with the bottom of joist The housing mounts with four 4 screws or nails S...

Страница 4: ...ille springs and insert them into tabs on each side of housing 8 Remove light lens Carefully insert a small flat blade screwdriver between grille and lens Pry lens out 7 Push grille against ceiling 9...

Страница 5: ...r nsito h desgaste natural del acabado i Productos en uso comercial o no residencial o j da os ocasionados por incendio inundaci n u otro caso fortuito Esta garant a cubre solamente Productos vendidos...

Страница 6: ...uador integral TAPA DE PARED con amortiguador integral CODO REDONDO DE 6 PULG CONDUCTO REDONDO DE 6 PULG CUBIERTA DE VENTILADOR Selle los huecos alrededor de la cubierta Sellar las juntas con cinta Ma...

Страница 7: ...acabada del techo Para techos de material de 1 2 de grueso posicione la parte inferior de cada soporte al ras con la parte inferior de cada viga INSTALE LA CUBIERTA Y EL CONDUCTO 2 Acople el conector...

Страница 8: ...ortes de la rejilla e ins rtelos en las ranuras que se encuentran a cada lado de la cubierta 7 Empuje la rejilla contra el cielo raso 4 Conecte los cables el ctricos Extienda el cableado de la casa de...

Отзывы: