Page 1

MODEL   QTRE100S  

WARNING  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-

JURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 

or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent 

power from being switched on accidentally. When the service 

disconnecting means cannot be locked, securely fasten a 

prominent warning device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by a qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-rated construction codes and standards.

4.  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equipment 

to prevent backdrafting. Follow the heating equipment manufac-

turer’s guideline and safety standards such as those published 

by the National Fire Protection Association (NFPA), and the 

American Society for Heating, Refrigeration and Air Condition-

ing Engineers (ASHRAE), and the local code authorities.

5.  When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7.  Acceptable for use over a tub or shower when connected to a 

GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.

8.  This unit must be grounded.

CAUTION  

1.  For general ventilating use only. Do not use to exhaust hazard-

ous or explosive materials and vapors.

2.  This product is designed for installation in flat ceilings only. DO 

NOT MOUNT THIS PRODUCT IN A WALL.

3.  To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power 

unit.

4.  Please read specification label on product for further information 

and requirements.

HUMIDITY SENSING FAN

READ AND SAVE THESE INSTRUCTIONS

CLEANING & MAINTENANCE

Installer: Leave this manual with the homeowner.

For quiet and efficient operation, long life, and attractive appear-

ance - lower or remove grille and vacuum interior of unit with the 

dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the 

motor bearings are making excessive or unusual noises, replace 

the motor / blower wheel assembly.

SENSOR CLEANING

The humidity sensor is mounted in the control housing. The sensor 

will operate most reliably when cleaned occasionally as follows:

1.  Disconnect power at service entrance.
2.  Remove the grille. Use a dry dustcloth, clean toothbrush, 

or lightly vacuum to clean sensor and grille. DO NOT USE 

ABRASIVE CLOTH, STEEL WOOL PADS, OR SCOURING 

POWDERS.

3.  DO NOT USE cleaning sprays, solvents, or water on or near 

the sensor!

OPERATION

The humidity control and fan can be operated separately. Use a 

1- or 2-function wall control. Do not use a dimmer switch to operate 

the humidity control. See “Connect Wiring” for details.

SENSOR OPERATION

The humidity-sensing

 

fan uses a sophisticated humidity sensor 

that responds to: (a) rapid to moderate increases in humidity or (b) 

humidity above a set-point. The humidity sensor may occasionally 

turn the fan ON when environmental conditions change.

MANUAL ON WITH TIMED OFF

The humidity sensing fan has an additional operation feature. For 

odor or vapor control, the fan can be energized by cycling the 

power switch. Once the fan has been energized in this manner, it 

will remain on for 20 minutes.
To manually energize the fan:

1.  If fan power switch is already ON, proceed to Step 2; otherwise, 

turn power switch ON for more than 1 second.

2.  Turn fan power switch OFF for less than 1 second.
3.  Turn fan power switch back ON and fan will turn ON.

To register this product visit: www.broan.com

Содержание QTRE100S

Страница 1: ...keep drywall spray construction dust etc off power unit 4 Please read specification label on product for further information and requirements HUMIDITY SENSING FAN READ AND SAVE THESE INSTRUCTIONS CLE...

Страница 2: ...ghest hole of each mounting flange and the I joist OR Locate unit above GFCI protected circuit required or within 5 feet of shower head Locate unit away from heating or cooling sources which can affec...

Страница 3: ...d hanger bars SCREW 2 HOLE FOR OPTIONAL SCREW MOUNTING 4 MOUNTING CHANNEL 2 NAIL 4 BOTTOM EDGE OF FRAMING 4 Connect electrical wiring Run 120 VAC house wiring to installation location Use proper UL ap...

Страница 4: ...TY OR FITNESS FOR A PARTICULAR PURPOSE During this three year period Broan will at its option repair or replace without charge any product or part which is found to be defective under normal use and s...

Страница 5: ...equilibrados mantenga la unidad de accionamiento al resguardo de rociados de yeso polvos de construcci n etc 4 L ase la etiqueta de especificaciones que tiene el producto para ver informaci n y requis...

Страница 6: ...que la unidad sobre o dentro de una distancia de 1 5 m 5 pies de la cabeza de la regadera se requiere un circuito protegido con un GFCI Ubique la unidad lejos de fuentes de calefacci n o en friamiento...

Страница 7: ...icos Extienda el cableado de la casa de 120 V CA al lugar de la instalaci n Utilice una conexi n aprobada por UL para afianzar el cableado de la casa a la placa de cableado Conecte los cables tal como...

Страница 8: ...ra original NO EXISTEN OTRAS GARANT AS EXPRESAS NI IMPL CITAS INCLUIDAS PERO SIN LIMITARSE A GARANT AS IMPL CITAS DE COMERCIALIZACI N O IDONEIDAD PARA UN PROP SITO PARTICULAR Durante este per odo de t...

Отзывы: