MODELS   QTRE080FLT • QTRE110FLT  

TYPICAL INSTALLATIONS

Housing mounted to I-joists.

Housing mounted anywhere be-

tween trusses using hanger bars.

PLAN THE INSTALLATION

The unit will operate most quietly and efficiently when located 
where the shortest possible duct run and minimum number 
of elbows will be needed.
Use  a  roof  cap  or  wall  cap  that  has  a  built-in  damper  to 
reduce backdrafts.
Plan to supply the unit with proper line voltage and appropri-
ate power cable.

Housing mounted anywhere be-

tween I-joists using hanger bars.

Housing mounted to joists.

Housing mounted anywhere be-

tween joists using hanger bars.

Housing mounted anywhere be-

tween trusses using hanger bars.

INSTALL HOUSING & DUCT

1a. Mount 

housing 

to joist or 

I

-joist.

Use a pliers to 

bend housing 

TABS

 out 

to 90

0

. Hold 

housing in 

place so that 

the housing 

tabs contact 

the bottom 

of the joist. 

The housing 

mounts with 

four (4) screws 

or nails. Screw 

or nail housing 

to joist through 

lowest holes in 

each mounting 

flange,  then 

through 

highest holes. 

SPACER

(use for mounting to I-Joist)

I

-JOIST

NOTE: Mounting to 

I

-JOIST

 (shown) requires use of 

SPACERS

 (included) between the highest hole of 

each mounting flange and the 

I

-joist.

OR

Cooking

Equipment

Floor

COOKING AREA

Do not install above or

inside this area.

45

o

45

o

NOT FOR USE IN

A COOKING AREA.

ROOF

CAP 

*

4-IN. ROUND

ELBOW(S) 

*

4-IN.

ROUND

DUCT 

*

WALL

CAP 

*

*

 Purchase

separately

INSULATION

(Can be placed 

around and over 

fan housing.)

FAN

HOUSING

TABS

Содержание QTRE080FLFT

Страница 1: ...RATION The fan light and night light can be operated separately Use a 3 function wall control Do not use a dimmer switch to operate the light See Connect Wiring for details Use of speed controls other...

Страница 2: ...mounted anywhere be tween trusses using hanger bars INSTALL HOUSING DUCT 1a Mount housing to joist or I joist Use a pliers to bend housing TABS out to 900 Hold housing in place so that the housing ta...

Страница 3: ...rywall Use the other set of holes not marked to mount the housing flush with the top of the drywall HANGER BAR 4 SCREWS 4 TAB Extend HANGER BARS to the width of the framing Hold ventilator in place wi...

Страница 4: ...Connector 4 3 98010102 Wiring Plate 4 99170245 Screw 8 18 X 375 5 97018011 Wire Panel Harness Assembly 6 97017855 Blower Assembly QTRE080FLT 97017856 Blower Assembly QTRE110FLT 7 97018273 Grille Asse...

Страница 5: ...endo ruido excesivo o inusual reemplace el conjunto del ventilador incluye el motor y el rodete del ventilador VENTILADOR L MPARA L MPARAS DE NOCHE SERIE QTRE A la persona que realiza la instalaci n D...

Страница 6: ...el ctrico apropiados O BIEN INSTALE LA CUBIERTA Y EL CONDUCTO 1a Instale la cubierta en las viguetas o viguetas I Con un alicate doble las LENG ETAS de la cubierta a 90 Sostenga la cubierta en su luga...

Страница 7: ...arca para montar la cubierta al ras con la parte superior de la tablarroca BARRA DE SUS PENSI N 4 TORNILLOS 4 LENG ETA STD CANAL DE MONTAJE 2 Abra las BARRAS DE SUSPENSI N hasta el ancho de la estruct...

Страница 8: ...cuidado in serte un destor nillador plano peque o entre la parilla y la lente de l mpara Haga palanca con el destornillador y saque la lente Al hacer el pedido de una pieza de servicio se debe especif...

Отзывы: